Architecture
Functions
- Number of function channels1
- Switching cyclesmin. 50000
- Power reserve≈ 200 h
Configuration
Main electrical features
Voltage
Electric current
- Max. power with cos phi 0.63 A
- Switching current at cos φ = 0.6max. 3 A
Dimensions
- Depth of installed product60 mm
- Height of installed product80 mm
- Width of installed product18 mm
- Width of rail mounted device (RMD)1 modules
Power
- Power consumed0.5 VA
- Power consumption (operation)0.5 VA
- Total power loss under IN1 W
- Loss power at full load≈ 1 W
- Power dissipation per coil0.5 W
Battery
- Charging time of the power reserve in hours120
Fluorescent bulbs control
- Compact fluorescent lampsmax. 100 W
Incandescent bulbs control
- Max. power with incandescent lamps900 W
- 230 V incandescent lamps and halogen lampsmax. 900 W
Installation, mounting
- Installation modefor mounting on DIN rail
Connection
- Connection cross-sect. flexible conductor1 / 4mm²
- Connection cross-sect. rigid cable1 / 4mm²
- Conductor cross-section (flexible)1…4 mm²
- Conductor cross-section (rigid)1…4 mm²
- Number of contacts1
- Type of contacts1 changeover
- Type of connectionwith screw terminals
Settings
- Number of program steps96
- Summer / Winter time changemanual
- Shortest switching time15 mn
- Type of programminganalog
- Program cyclesProgramme cycle: 24 hours
- Programming cycle24H
Equipment
- Number of channels1
- Number of switching times for on/off96
- Supply failure reserve200 h
- Switching cycles at cos φ = 0,6min. 20000
Use
Safety
Use conditions
- Operating temperature-10…55 °C
- Working accuracy1
- Storage/transport temperature-10…55 °C