Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric A9N61518 Miniature Circuit Breaker - C60H - 1 Pole - 50 a - C Curve
Schneider Electric A9N61518 Miniature Circuit Breaker - C60H - 1 Pole - 50 a - C Curve
Image
Image
Specifications
infotip-icon
View other Miniature Circuit Breakers - MCBs dimensions or variations
Please select at least one specification below.
Range
Acti9
Poles Description
1P
Network Type
DC
Number of Protected Poles
1
[In] Rated Current
50 A at 25 °C
Curve Code
C
Breaking Capacity
10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu at 220 V DC conforming to IEC 60947-2 6 kA Icu at 250 V DC conforming to EN 60947-2 6 kA Icu at 250 V DC conforming to IEC 60947-2 20 kA Icu at 110 V DC conforming to EN 60947-2 20 kA Icu at 110 V DC conforming to IEC 60947-2
Standards
EN 60947-2 IEC 60947-2
Ambient Air Temperature for Operation
-25…70 °C
Mechanical Durability
20000 cycles
Ambient Air Temperature for Storage
-40…85 °C
Electrical Durability
3000 cycles L/R = 2 ms
Tightening Torque
Power circuit: 2.5 N.m top or bottom
Colour
White
This spec is not available in the specification table.
Trip Unit Technology
Thermal-magnetic
This spec is not available in the specification table.
Control Type
Toggle
This spec is not available in the specification table.
Device Short Name
C60H-DC
This spec is not available in the specification table.
Product Name
Acti9 C60H-DC
This spec is not available in the specification table.
Device Application
Distribution
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Network Frequency
50/60 Hz
This spec is not available in the specification table.
Utilisation Category
Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to IEC 60947-2 Yes conforming to EN 60947-2
This spec is not available in the specification table.
[Ics] Rated Service Breaking Capacity
15 kA 75 % conforming to EN 60947-2 - 110 V DC 15 kA 75 % conforming to IEC 60947-2 - 110 V DC 4.5 kA 75 % conforming to EN 60947-2 - 250 V DC 4.5 kA 75 % conforming to IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN 60947-2 - 220 V DC 7.5 kA 75 % conforming to IEC 60947-2 - 220 V DC
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
500 V DC conforming to IEC 60947-2 500 V DC conforming to EN 60947-2
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
This spec is not available in the specification table.
Contact Position Indicator
Yes
This spec is not available in the specification table.
Mounting Support
35 mm symmetrical DIN rail
This spec is not available in the specification table.
Local Signalling
ON/OFF indication
This spec is not available in the specification table.
Overvoltage Category
IV
This spec is not available in the specification table.
Comb Busbar and Distribution Block Compatibility
Top or bottom: standard
This spec is not available in the specification table.
9 mm Pitches
2
This spec is not available in the specification table.
Pollution Degree
3 conforming to EN 60947-2 3 conforming to IEC 60947-2
This spec is not available in the specification table.
Operating Altitude
2000 m
This spec is not available in the specification table.
Earth-Leakage Protection
Without
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
250 V DC
This spec is not available in the specification table.
Locking Options Description
In position O
This spec is not available in the specification table.
Provision for Padlocking
Padlockable
This spec is not available in the specification table.
Tropicalisation
2 conforming to IEC 60068-2
This spec is not available in the specification table.
Product Description

Schneider Electric A9N61518 Miniature Circuit Breaker (mcb), Acti9 C60H-DC, 1P, 50A, C Curve, 6kA (IEC/EN 60947-2)

This Acti9 C60H-DC is a low voltage direct current miniature circuit breaker (MCB). It has 1P, rated current 50A and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VDC conforming to EN 60947-2 standard and 10kA at 220VDC conforming to EN 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. It offers VisiTrip for safety during maintenance and VisiSafe to reduce intervention time. The Acti9 C60H-DC is used in direct current circuit (industrial control and automation, transport, renewable energy). This device is dedicated to industrial control, automations, transport and renewable energy applications. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 250VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The weight is 0.128kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Miniature Circuit Breakers - MCBs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Miniature Circuit Breakers - MCBs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image