Schneider Electric LR97D07M7 Electronic Overload Relay for Motor Tesys - 1.2...7 a - 200...240 V Ac
Schneider Electric LR97D07M7 Electronic Overload Relay for Motor Tesys - 1.2...7 a - 200...240 V Ac
Image
Image
Technical Data Sheets
Product Description

Schneider Electric LR97D07M7 Electronic Overload Relay for Motor Tesys - 1.2...7 a - 200...240 V Ac

TeSys LR97D electronic overcurrent relay, 7A/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 1.2-6A. It provides 3 dials to adjust the protection, LOAD (1.2-7A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec.

Settings also include selectors for 1-phase/3-phase motors and manual/automatic reset, the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signaling. Settings can be locked by sealing the transparent cover.

For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach.

AU $ 189.72
Quantity:
/ EA
This item is sold by
Image
MY-2155714050
Shop by Specification Table
You can find items with similar specifications from the table below.
Overload Relays
25 Items
overload-relays-img
Network Type
AC, AC DC, DC AC
Network Frequency
0...400 Hz, <= 400 Hz, 50/60 Hz, 50...60 Hz
Standards
BS 4941 VDE 0660 IEC 60947 NF C 63-650, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495, IEC 60255-6 IEC 60947
[Ui] Rated Insulation Voltage
Power circuit: 1000 V AC conforming to IEC 60947-4, Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL, Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC conforming to UL Power circuit: 690 V AC conforming to IEC 60947-4-1, Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1, Power circuit: 690 V conforming to BS 4941 Power circuit: 690 V conforming to IEC 60947 Power circuit: 750 V conforming to VDE 0110 group C Power circuit: 600 V conforming to CSA C22.2 No 14
[Uimp] Rated Impulse Withstand Voltage
6 kV, 6 kV conforming to IEC 60947-1, 8 kV conforming to IEC 60947-1
Ambient Air Temperature For Operation
-20…55 °C conforming to IEC 60255-8, -20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947, -20…60 °C without derating conforming to IEC 60947-4-1, -25…60 °C conforming to IEC 60947-4-1, -25…60 °C without derating conforming to IEC 60947-4-1
Ambient Air Temperature For Storage
-30…80 °C, -40…70 °C, -40…85 °C, -60…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Overload Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Overload Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image