Schneider Electric LR9F5369 Electronic Thermal Overload Relay - Tesys Lrf
Schneider Electric LR9F5369 Electronic Thermal Overload Relay - Tesys Lrf
Image
Image
Specifications
infotip-icon
View other Overload Relays dimensions or variations
Please select at least one specification below.
Network Type
AC
Network Frequency
50/60 Hz
Standards
VDE 0660 IEC 60255-17 IEC 60947-4-1 IEC 60255-8 EN 60947-4-1
[Ui] Rated Insulation Voltage
Power circuit: 1000 V AC conforming to IEC 60947-4
[Uimp] Rated Impulse Withstand Voltage
8 kV conforming to IEC 60947-1
Ambient Air Temperature For Operation
-20…55 °C conforming to IEC 60255-8
Ambient Air Temperature For Storage
-40…85 °C
[Ith] Conventional Free Air Thermal Current
5 A for control circuit
Thermal Protection Adjustment Range
90…150 A
Local Signalling
Trip indicator
This spec is not available in the specification table.
Control Type
Dial white full-load current adjustment Test button red Push-button red reset Push-button stop
This spec is not available in the specification table.
Device Short Name
LR9F
This spec is not available in the specification table.
Product Or Component Type
Electronic thermal overload relay
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys LRF
This spec is not available in the specification table.
Mounting Support
Direct on contactor Plate
This spec is not available in the specification table.
Connections - Terminals
Control circuit: screw clamp terminals 1 cable 0.75…2.5 mm² - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable 0.75…2.5 mm² - cable stiffness: solid Control circuit: screw clamp terminals 1 cable 0.75…4 mm² - cable stiffness: flexible - without cable end Control circuit: screw clamp terminals 2 cable 1…1.5 mm² - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 2 cable 1…2.5 mm² - cable stiffness: flexible - without cable end Control circuit: screw clamp terminals 2 cable 1 mm² - cable stiffness: solid Power circuit: lugs-ring terminals M8
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 conforming to IEC 60529 IP20 conforming to VDE 0106
This spec is not available in the specification table.
Operating Altitude
<= 2000 m without derating
This spec is not available in the specification table.
Tightening Torque
Control circuit: 1.2 N.m on screw clamp terminals Power circuit: 18 N.m on screw clamp terminals
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
1000 V AC 50/60 Hz for power circuit conforming to VDE 0110 group C
This spec is not available in the specification table.
Electromagnetic Compatibility
Resistance to electrostatic discharge: 6 kV in indirect mode conforming to IEC 61000-4-2 Resistance to electrostatic discharge: 8 kV in air conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test: 10 V/m conforming to IEC 61000-4-3 Fast transients immunity test: 2 kV conforming to IEC 61000-4-4
This spec is not available in the specification table.
Product Certifications
UL CSA UKCA
This spec is not available in the specification table.
Protective Treatment
TH
This spec is not available in the specification table.
Fire Resistance
850 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Mechanical Robustness
Shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations 5...300 Hz: 2 GN conforming to IEC 60068-2-6
This spec is not available in the specification table.
Phase Failure Sensitivity
Tripping in 4 s +/- 20 % conforming to IEC 60947-4-1
This spec is not available in the specification table.
Contacts Type And Composition
1 NO + 1 NC
This spec is not available in the specification table.
Product Compatibility
LC1F115...LC1F185
This spec is not available in the specification table.
Tripping Threshold
1.12 +/- 0.06 In tripping conforming to IEC 60947-4-1
This spec is not available in the specification table.
Relay Application
Motor protection
This spec is not available in the specification table.
Dielectric Strength
6 kV 50 Hz conforming to IEC 255-5
This spec is not available in the specification table.
Surge Withstand
4 kV conforming to IEC 61000-4-5
This spec is not available in the specification table.
Reset
Manual reset on front relay
This spec is not available in the specification table.
Thermal Overload Class
Class 10 conforming to IEC 60947-4
This spec is not available in the specification table.
Temperature Compensation
-20…70 °C
This spec is not available in the specification table.
Maximum Voltage Drop
<2.5 V closed state
This spec is not available in the specification table.
Current Consumption
<= 5 mA no-load
This spec is not available in the specification table.
Switching Capacity For Alarm
0...150 mA
This spec is not available in the specification table.
Product Description
AU $ 1,029.61
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Overload Relays
53 Items
overload-relays-img
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5, IEC 60255-17 IEC 60947-4-1 IEC 60255-8 VDE 0660 EN 60947-4-1, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
[Ui] Rated Insulation Voltage
Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC conforming to UL Power circuit: 690 V AC conforming to IEC 60947-4-1, Power circuit: 1000 V AC conforming to IEC 60947-4, Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1, Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL, Power circuit: 1000 V conforming to IEC 60947-4-1
Ambient Air Temperature For Operation
-20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947, -20…55 °C conforming to IEC 60255-8, -20…60 °C without derating conforming to IEC 60947-4-1, -25 → +60 °C, -20 → +60 °C
[Ith] Conventional Free Air Thermal Current
6 A for signalling circuit, 3 A for signalling circuit, 5 A for signalling circuit, 3 A for control circuit, 5 A for control circuit
Thermal Protection Adjustment Range
80…104 A, 30…40 A, 30…38 A, 48…65 A, 110…140 A
[Us] Rated Supply Voltage
100...120 V AC, 200...240 V AC, 24 V DC, 24 V ac/dc, 690 V ac
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Overload Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Overload Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image