Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric METSEPM8240 Power Quality Meter, Powerlogic PM8000, Standard, Integrated Display, 512 Mb, 256 s/c
Schneider Electric METSEPM8240 Power Quality Meter, Powerlogic PM8000, Standard, Integrated Display, 512 Mb, 256 s/c
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Power & Energy Meters dimensions or variations
Please select at least one specification below.
Range
PowerLogic
Poles Description
3P + N 3P 1P + N
[In] Rated Current
1 A 5 A 10 A
Type of Measurement
Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms
Display Type
Colour TFT LCD
Standards
IEC 61557-12 IEC 62052-11 IEC 62053-24 IEC 62053-22 IEEE 1588 IEC 62586-2 IEC 61326-1
Ambient Air Temperature for Operation
-25…70 °C
Width
96 mm
This spec is not available in the specification table.
Device Short Name
PM8240
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
PowerLogic PM8000
This spec is not available in the specification table.
Depth
77.5 mm
This spec is not available in the specification table.
Device Application
Power monitoring WAGES metering
This spec is not available in the specification table.
Mounting Support
Framework
This spec is not available in the specification table.
Height
96 mm
This spec is not available in the specification table.
Mounting Mode
Flush-mounted
This spec is not available in the specification table.
Accuracy class
Class 0.2S active energy conforming to IEC 62053-22 Class 0.2 active energy conforming to ANSI C12.20 Class 0.2 active power conforming to IEC 61557-12 Class 0.5S reactive energy conforming to IEC 62053-24 Class 0.5 power factor conforming to IEC 61557-12 Class 0.2 voltage conforming to IEC 61557-12 Class 0.2 current conforming to IEC 61557-12
This spec is not available in the specification table.
Network Frequency
50 Hz 60 Hz
This spec is not available in the specification table.
Sampling rate
256 samples/cycle
This spec is not available in the specification table.
Measurement current
50…10000 mA
This spec is not available in the specification table.
Communication Port Protocol
Modbus RTU at 115 kbauds - 2-wire ION at 115 kbauds - 2-wire DNP3 IEC 61850 Modbus TCP/IP Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s RSTP 801.1d 2004
This spec is not available in the specification table.
Communication port support
ETHERNET Screw terminal block: RS485
This spec is not available in the specification table.
Number of inputs
3 digital 30 V AC 3 digital 60 V DC
This spec is not available in the specification table.
Number of outputs
1 pulse
This spec is not available in the specification table.
Product certifications
CE CULus N998
This spec is not available in the specification table.
IP Degree of Protection
IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529
This spec is not available in the specification table.
Relative Humidity
5…95 %
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
3000 m
This spec is not available in the specification table.
Power quality analysis
conforming to EN 50160: 2010 compliance report conforming to IEEE 519: 2014 compliance report conforming to IEC 61000-4-30: class S power quality measurement up to the 63rd harmonic harmonic distortion waveform capture voltage sag and swell detection programmablity (logic and math functions) conforming to IEC 62586 power quality monitoring disturbance direction detection rapid voltage change
This spec is not available in the specification table.
supply voltage
90...415 V AC 45...65 Hz +/- 10 % 110...415 V DC +/- 10 %
This spec is not available in the specification table.
Display resolution
320 x 240 pixels QVGA
This spec is not available in the specification table.
Analogue input type
Voltage (impedance 5 MOhm) Current (impedance 0.3 mOhm)
This spec is not available in the specification table.
Measurement voltage
57…400 V AC 42...69 Hz between phase and neutral 100…690 V AC 42...69 Hz between phases
This spec is not available in the specification table.
Frequency measurement range
42…69 Hz
This spec is not available in the specification table.
Measurement accuracy
Current +/- 0.1 % Voltage +/- 0.1 % Active energy +/- 0.2 %
This spec is not available in the specification table.
data recording
Min/max of instantaneous values Waveform logs Sequence of event recording Time stamping Alarm logs Trending/forecasting Sag and swell logs Harmonics logs GPS synchronisation Data logs Event logs 50 data recorders
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Immunity to impulse waves conforming to IEC 61000-4-12 Conducted and radiated emissions conforming to EN 55022 Conducted and radiated emissions conforming to EN 55011 Conducted and radiated emissions conforming to FCC part 15 Conducted and radiated emissions conforming to ICES-003 Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579 Surge withstand conforming to IEEE C37.90.1
This spec is not available in the specification table.
Information displayed
Voltage Current Frequency Power Energy consumption Harmonic distortion
This spec is not available in the specification table.
memory capacity
512 MB
This spec is not available in the specification table.
Power consumption in VA
18 VA at 415 V AC
This spec is not available in the specification table.
Web services
Customizable home page File upload/download via FTP File upload/download via SFTP Web server Alarm notification by e-mail Viewing of captured waveform (FTP) Viewing of captured waveform (web) HTTPS server
This spec is not available in the specification table.
Cybersecurity
Enable/disable communication ports Password protection Syslog protocol support Robust security logs Port hardening
This spec is not available in the specification table.
Communication Service
SMTP e-mail notification RSTP support NTP time synchronization DHCP PTP time synchronization
This spec is not available in the specification table.
Communication network type
IPv6 (internet protocol)
This spec is not available in the specification table.
installation category
III
This spec is not available in the specification table.
Safety Construction
III400…690 V conforming to IEC 61010-1:ed. 3 III400…690 V conforming to EN 61010-1:ed. 3 III347…600 V conforming to UL 61010-1:ed. 3 III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
This spec is not available in the specification table.
Product Description
AU $ 13,766.88
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
23 Items
power-energy-meters-img
Poles Description
3P 1P + N 3P + N, 3P + N 1P + N 3P, 1P + N 3P 3P + N, 3P 3P + N 1P + N, 3P + N 3P 1P + N
[In] Rated Current
1 A 5 A, 125 A, 63 A, 1 A 5 A 10 A, 5 A 1 A
Type of Measurement
Active energy Current Voltage Active power, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms, Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total, Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Apparent energy total Active and reactive energy total Apparent power total Active and reactive power total Current average Voltage average Frequency average Power factor average
Display Type
Monochrome graphic LCD, Colour TFT LCD, 7 segments LED, Backlit LCD, TFT LCD
Standards
IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-24 EN 50470-3 IEC 62053-22:2020 IEC 61557-12:2015 ANSI C12.20 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-1 IEC 62053-24 IEC 60529 UL 61010-1 IEC 62053-22:2020 EN 50470-3 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, UL 61010-1 EN 50470-3 EN 50470-1 IEC 62053-22:2020 IEC 60529 IEC 62053-24 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
Ambient Air Temperature for Operation
-25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display, -25…55 °C - MID -25…70 °C - IEC -25…60 °C - IEC, -25…70 °C - IEC, -10…60 °C, -25…70 °C
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image