• Elegant and easy-to-use cabinet
• Large display with 6000 counts and Backlight
• Enhanced current measuring function using an external clamp sensor
• Two detachable holders, flat and wing type
• Accurate reading with True RMS
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
6.000/60.00/600.0V (auto range)
±0.5%rdg ±3dgt
600.0mV
±1.5%rdg ±3dgt
60.00/200.0A (auto range)
±1.5%rdg ±3dgt + Sensor accuracy
6.000/60.00/600.0V (auto range)
±1.0%rdg ±3dgt [40 – 500Hz]
600.0mV
±2.0%rdg ±3dgt [40 – 500Hz]
60.00/200.0A (auto range)
±2.0%rdg ±3dgt + Sensor accuracy [40 – 500Hz]
6.000/10.00A (auto range)
±1.5%rdg ±3dgt
6.000/10.00A (auto range)
±1.5%rdg ±3dgt[45 – 500Hz]
600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range)
±0.5%rdg ±4dgt (600Ω),
±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ)
±1.5%rdg ±3dgt (40MΩ)
600Ω (Buzzer sounds below 90Ω)
Open-loop voltage: < 3.0V
60.00/600.0nF/6.000/60.00/600.0/1000µF
±2.0%rdg ±5dgt (60/600nF)
±5.0%rdg ±5dgt (6/60/600/1000µF)
ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt
ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt
10.0 – 90.0% ±1.0%rdg ±3dgt [50/60Hz]
IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V
IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS)
R03 (1.5V) × 2
155(L) × 75(W) × 40(D)mm
250g Approx. (including batteries)
Wing-type holder, Flat-type holder, 7066A (Test leads),
8919 (Ceramic fuse [10A/600V]) × 1 (included),
9097 (Carrying case), R03 × 2, Instruction manual