Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric A9F74406 iC60N - Miniature Circuit Breaker - 4P - 6A - C Curve
Schneider Electric A9F74406 iC60N - Miniature Circuit Breaker - 4P - 6A - C Curve
Image
Image
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Miniature Circuit Breakers - MCBs dimensions or variations
Please select at least one specification below.
Range
Acti9
Poles Description
4P
Network Type
DC AC
Number of Protected Poles
4
[In] Rated Current
6 A
Curve Code
C
Breaking Capacity
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
Standards
EN 60898-1 IEC 60947-2 IEC 60898-1 EN 60947-2
Magnetic Tripping Limit
8 x In +/- 20 %
Connection - Terminals
Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible
IP Degree of Protection
IP20 conforming to IEC 60529 IP20 conforming to EN 60529
Ambient Air Temperature for Operation
-35…70 °C
Mechanical Durability
20000 cycles
Ambient Air Temperature for Storage
-40…85 °C
Electrical Durability
10000 cycles
Tightening Torque
2 N.m top or bottom
Colour
White
This spec is not available in the specification table.
Width
72 mm
This spec is not available in the specification table.
Trip Unit Technology
Thermal-magnetic
This spec is not available in the specification table.
Control Type
Toggle
This spec is not available in the specification table.
Device Short Name
IC60N
This spec is not available in the specification table.
Product Name
Acti9 iC60
This spec is not available in the specification table.
Depth
78.5 mm
This spec is not available in the specification table.
Device Application
Distribution
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Network Frequency
50/60 Hz
This spec is not available in the specification table.
Utilisation Category
Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2
This spec is not available in the specification table.
[Ics] Rated Service Breaking Capacity
15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 180...250 V DC 10 kA 100 % conforming to EN 60947-2 - 180...250 V DC
This spec is not available in the specification table.
Limitation Class
3 conforming to EN 60898-1 3 conforming to IEC 60898-1
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
This spec is not available in the specification table.
Contact Position Indicator
Yes
This spec is not available in the specification table.
Mounting Support
DIN rail
This spec is not available in the specification table.
Local Signalling
Trip indicator
This spec is not available in the specification table.
Overvoltage Category
IV
This spec is not available in the specification table.
Comb Busbar and Distribution Block Compatibility
Top or bottom: YES
This spec is not available in the specification table.
9 mm Pitches
8
This spec is not available in the specification table.
Height
85 mm
This spec is not available in the specification table.
Pollution Degree
3 conforming to EN 60947-2 3 conforming to IEC 60947-2
This spec is not available in the specification table.
Relative Humidity
95 % at 55 °C
This spec is not available in the specification table.
Operating Altitude
0...2000 m
This spec is not available in the specification table.
Wire Stripping Length
14 mm for top or bottom connection
This spec is not available in the specification table.
Earth-Leakage Protection
Separate block
This spec is not available in the specification table.
Tropicalisation
2 conforming to IEC 60068-1
This spec is not available in the specification table.
Product Description

Schneider Electric A9F74406 Miniature Circuit Breaker (mcb), Acti9 iC60N, 4P, 6A, C Curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)

This Acti9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 4P circuit breaker with 4 protected poles, 6A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 400VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 8 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 85mm x (D) 78.5mm. The weight is 0.5kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Miniature Circuit Breakers - MCBs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Miniature Circuit Breakers - MCBs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image