Local Signalling
1 LED (red) for DC bus energized
Range of Product
Altivar 212
Accuracy
+/- 0.6 % (VIA) for a temperature variation 60 °C +/- 0.6 % (VIB) for a temperature variation 60 °C +/- 1 % (FM) for a temperature variation 60 °C
Standard
EN 55011 class A group 1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C1 EN 61800-3 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 61800-5-1 IEC 61800-3 environments 1 category C1 UL Type 1 IEC 61800-3 category C2 IEC 61800-3 IEC 61800-3 IEC 61800-3 environments 1 category C1 IEC 61800-3 category C2 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C3 IEC 61800-5-1
IP Degree of Protection
IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to IEC 60529 IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529 IP41 on upper part conforming to IEC 61800-5-1 IP41 on upper part conforming to IEC 60529
Ambient Air Temperature for Operation
-10…40 °C (without derating) 40…50 °C (with derating factor)
Ambient Air Temperature for Storage
-25…70 °C
Operating Altitude
1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating
Vibration Resistance
1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
[Us] Rated Supply Voltage
380...480 V - 15...10 %
Supply Frequency
50...60 Hz - 5...5 %
Switching Frequency
6...16 kHz adjustable 12...16 kHz with derating factor
Noise Level
51 dB conforming to 86/188/EEC
Sampling Duration
2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog
Continuous Output Current
2.2 A at 380 V 2.2 A at 460 V
Width
107 mm
This spec is not available in the specification table.
Device Short Name
ATV212
This spec is not available in the specification table.
Product or Component Type
Variable speed drive
This spec is not available in the specification table.
Depth
150 mm
This spec is not available in the specification table.
Height
143 mm
This spec is not available in the specification table.
Network Frequency
47.5...63 Hz
This spec is not available in the specification table.
Pollution Degree
2 conforming to IEC 61800-5-1
This spec is not available in the specification table.
Relative Humidity
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3
This spec is not available in the specification table.
Marking
CE
This spec is not available in the specification table.
Environmental Characteristic
Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3
This spec is not available in the specification table.
Analog Input Type
VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
This spec is not available in the specification table.
Motor Power kW
0.75 kW
This spec is not available in the specification table.
Motor Power hp
1 hp
This spec is not available in the specification table.
Minimum Switching Current
3 mA at 24 V DC for configurable relay logic
This spec is not available in the specification table.
Insulation Resistance
>= 1 mOhm 500 V DC for 1 minute
This spec is not available in the specification table.
Certifications
UL NOM 117 CSA C-Tick
This spec is not available in the specification table.
Operating Position
Vertical +/- 10 degree
This spec is not available in the specification table.
Product Specific Application
Pumps and fans in HVAC
This spec is not available in the specification table.
Shock Resistance
15 gn for 11 ms conforming to IEC 60068-2-27
This spec is not available in the specification table.
Protection Type
Overheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor
This spec is not available in the specification table.
Connector Type
1 open style 1 RJ45
This spec is not available in the specification table.
Product Destination
Asynchronous motors
This spec is not available in the specification table.
Output Voltage
<= power supply voltage
This spec is not available in the specification table.
Analogue Input Number
2
This spec is not available in the specification table.
Assembly Style
With heat sink
This spec is not available in the specification table.
Maximum Switching Current
5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
This spec is not available in the specification table.
Electrical Connection
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14 L1/R, L2/S, L3/T: terminal 6 mm² / AWG 10
This spec is not available in the specification table.
Network Number of Phases
3 phases
This spec is not available in the specification table.
Communication Service
Read device identification (43) Time out setting from 0.1 to 100 s Write single register (06) Write multiple registers (16) 2 words maximum Monitoring inhibitable Read holding registers (03) 2 words maximum
This spec is not available in the specification table.
Transient Overtorque
120 % of nominal motor torque +/- 10 % for 60 s
This spec is not available in the specification table.
Speed Accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
This spec is not available in the specification table.
Supply Voltage Limits
323…528 V
This spec is not available in the specification table.
Dielectric Strength
3535 V DC between earth and power terminals 5092 V DC between control and power terminals
This spec is not available in the specification table.
Response Time
FM 2 ms, tolerance +/- 0.5 ms for analog output(s) FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
This spec is not available in the specification table.
Type of Cable
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
This spec is not available in the specification table.
Motor Starter Type
Variable speed drive
This spec is not available in the specification table.
Functionality
Mid
This spec is not available in the specification table.
Spesific Application
HVAC
This spec is not available in the specification table.
Torque Accuracy
+/- 15 %
This spec is not available in the specification table.
Air Flow
19 m3/h
This spec is not available in the specification table.
Tightening Torque
1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T) 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
This spec is not available in the specification table.
Product Description

Schneider Electric ATV212H075N4 0.75kW - Variable Speed Drive ATV212

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 2kg and its dimensions are, 107mm wide, 143mm high, 150mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It can also be mounted directly on a 35 mm wide DIN rail, thanks to the kit VW3A31852, to order separately. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is labeled Green Premium and complies with environmental protection directives such as RoHS, WEEE, etc.

S$ 1,419.05
Quantity:
EA
This item is sold by
Image
MY-5151010243
Shop by Specification Table
You can find items with similar specifications from the table below.
Inverter Drives
13 Items
inverter-drives-img
Local Signalling
1 LED (red) for DC bus energized, Local diagnostic: 3 LED (mono/dual colour) Embedded communication status: 5 LED (dual colour) Communication module status: 2 LED (dual colour) Presence of voltage: 1 LED (red), 3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage 3 LEDs for local diagnostic
Range of Product
Altivar Machine ATV320, Altivar Process ATV900, Altivar 12, Easy Altivar 310, Altivar 212
Mounting Mode
Wall mount, Cabinet mount, Wall Mount, DIN Rail, Cabinet Mount
Standard
IEC 61800-3 category C3 IEC 61800-3 category C2 EN 61800-3 category C3 EN 55011 class A group 1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 2 category C2 IEC 61800-3 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-5-1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-5-1 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 UL Type 1, CE, CSA, UL, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, NOM 117, RCM, UL, ATEX, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, TUV, UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 13849-1, IEC 60721-3, IEC 61000-3-12, IEC 61508, UL 508C
IP Degree of Protection
IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529, IP20 without blanking plate on upper part IP40 top, IP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1, IP55, IP54
Ambient Air Temperature for Operation
-10…50 °C without derating 50…60 °C with derating factor, -10…40 °C without derating 40…60 °C with current derating 2.2 % per °C, -10…55 °C without derating 55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C, 40…50 °C (with derating factor) -15…40 °C (without derating), -10…40 °C (without derating) 40…50 °C (with derating factor)
Operating Altitude
<= 1000 m without derating, 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating, > 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating, <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m, 1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Inverter Drives from SCHNEIDER ELECTRIC
Source & compare similar products
More from Inverter Drives
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image