Schneider Electric A9R16480 Residual Current Circuit Breaker (rccb), Acti9 Iid, 4P, 80A, Ac Type, 500mA
Schneider Electric A9R16480 Residual Current Circuit Breaker (rccb), Acti9 Iid, 4P, 80A, Ac Type, 500mA
Image
Image
Specifications
infotip-icon
View other Residual Current Circuit Breakers - RCCBs dimensions or variations
Please select at least one specification below.
Colour
White
Poles Description
4P
[In] Rated Current
80 A
Earth-Leakage Sensitivity
500 mA
Network Frequency
50/60 Hz
Standards
EN/IEC 61008-1
[Ui] Rated Insulation Voltage
500 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage
6 kV
Tightening Torque
3.5 N.m top or bottom
Rated Breaking And Making Capacity
Idm 1500 A Im 1500 A
Rated Conditional Short-Circuit Current
10 kA
Control Type
Toggle
This spec is not available in the specification table.
Device Short Name
iID
This spec is not available in the specification table.
Range
Acti9
This spec is not available in the specification table.
Network Type
AC
This spec is not available in the specification table.
Neutral Position
Left
This spec is not available in the specification table.
Mounting Mode
Clip-on
This spec is not available in the specification table.
Contact Position Indicator
Yes
This spec is not available in the specification table.
Mounting Support
DIN rail
This spec is not available in the specification table.
Connections - Terminals
Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule
This spec is not available in the specification table.
9 Mm Pitches
8
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-5…60 °C
This spec is not available in the specification table.
Mechanical Durability
20000 cycles
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…85 °C
This spec is not available in the specification table.
Electrical Durability
AC-1: 10000 cycles
This spec is not available in the specification table.
Wire Stripping Length
14 mm for top or bottom connection
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
380...415 V AC 50/60 Hz
This spec is not available in the specification table.
Electromagnetic Compatibility
8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
This spec is not available in the specification table.
Earth-Leakage Protection Time Delay
Instantaneous
This spec is not available in the specification table.
Earth-Leakage Protection Class
Type AC
This spec is not available in the specification table.
Device Location In System
Outgoer
This spec is not available in the specification table.
Residual Current Tripping Technology
Voltage independent
This spec is not available in the specification table.
Locking Options Description
Padlocking device
This spec is not available in the specification table.
Surge Current
250 A
This spec is not available in the specification table.
Product Description
US $ 173.09
Quantity:
EA
This item is sold by
Image
MY-0408537236
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Residual Current Circuit Breakers - RCCBs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Residual Current Circuit Breakers - RCCBs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image