Schneider Electric ATV930C11N4C Variable Speed Drive - ATV930 - 110kW - 400/480V - w/o Braking Unit - IP00
Schneider Electric ATV930C11N4C Variable Speed Drive - ATV930 - 110kW - 400/480V - w/o Braking Unit - IP00
Image
Image
Product Description

Schneider Electric ATV930C11N4C Variable Speed Drive - ATV930 - 110kW - 400/480V - w/o Braking Unit - IP00

The Altivar Process ATV900 variable speed drive is designed to power 3-phase synchronous and asynchronous motors. It supports motors with a power rating of up to 110 kW / 150 HP for applications requiring slight overload (up to 120%) and up to 90 kW / 125 HP for applications requiring significant overload (up to 150%). The drive operates at a rated supply voltage of 380 Vac to 480 Vac.

This variable speed/frequency drive (VSD/VFD) is specifically engineered for industrial processes across several market segments, including oil and gas, mining, minerals and metals, food and beverage, and water and wastewater. It provides high motor performance and total control for any motor configuration in master/slave applications.

Key Features:

  • Network Services: Ensure operational continuity even during connection breakdowns.
  • Web Server and Data Logging: Facilitate quick troubleshooting and preventive maintenance to reduce downtime.
  • Advanced Connectivity: Includes EtherNet/IP and Modbus TCP for deep integration into automation architectures.
US $ 22,563.60
Quantity:
EA
This item is sold by
Image
MY-5151010243
Shop by Specification Table
You can find items with similar specifications from the table below.
Inverter Drives
13 Items
inverter-drives-img
Local Signalling
3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, Local diagnostic: 3 LED (mono/dual colour) Embedded communication status: 5 LED (dual colour) Communication module status: 2 LED (dual colour) Presence of voltage: 1 LED (red), 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage 3 LEDs for local diagnostic, 1 LED (red) for DC bus energized
Range of Product
Altivar Process ATV600, Altivar 12, Altivar Machine ATV320, Easy Altivar 310, Altivar 212
Mounting Mode
Wall mount, Cabinet mount, Wall Mount, DIN Rail, Cabinet Mount
Standard
IEC 61800-3 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 UL Type 1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C2 IEC 61800-3 IEC 61800-3 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-5-1 EN 55011 class A group 1 IEC 61800-3 environments 2 category C2 EN 61800-3 category C3 IEC 61800-5-1 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C1, CE, CSA, UL, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, NOM 117, RCM, UL, ATEX, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, TUV, UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 13849-1, IEC 60721-3, IEC 61000-3-12, IEC 61508, UL 508C
IP Degree of Protection
IP20, IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to IEC 60529 IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529 IP41 on upper part conforming to IEC 61800-5-1 IP41 on upper part conforming to IEC 60529, IP55 conforming to IEC 61800-5-1 IP55 conforming to IEC 60529, IP55, IP54
Ambient Air Temperature for Operation
-10…50 °C without derating 50…60 °C with derating factor, -10…55 °C without derating 55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C, 40…50 °C (with derating factor) -15…40 °C (without derating), -15…50 °C (without derating) 50…60 °C (with derating factor), -10…40 °C (without derating) 40…50 °C (with derating factor)
Operating Altitude
<= 3000 m with current derating above 1000m, <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m, 1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating, 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating, <= 1000 m without derating
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Inverter Drives from SCHNEIDER ELECTRIC
Source & compare similar products
More from Inverter Drives
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image