Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Schneider Electric METSEPM3255 PM3255 Power Meter - 2 Digital I - 2 Digital O - RS485
Schneider Electric METSEPM3255 PM3255 Power Meter - 2 Digital I - 2 Digital O - RS485
Image
Image
Specifications
infotip-icon
View other Power & Energy Meters dimensions or variations
Please select at least one specification below.
Range
PowerLogic
[In] Rated Current
5 A 1 A
Type of Measurement
Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U)
Display Type
Backlit LCD
Standards
BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
Ambient Air Temperature for Operation
-25…70 °C
Width
90 mm
This spec is not available in the specification table.
Device Short Name
PM3255
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
PowerLogic PM3000
This spec is not available in the specification table.
Depth
70 mm
This spec is not available in the specification table.
Device Application
Multi-tariff Power monitoring Sub billing
This spec is not available in the specification table.
Mounting Support
DIN rail
This spec is not available in the specification table.
Height
95 mm
This spec is not available in the specification table.
Mounting Mode
Clip-on
This spec is not available in the specification table.
Accuracy class
Class 0.5S active energy conforming to IEC 62053-22 Class 1 active energy conforming to IEC 62053-21 Class 2 reactive energy conforming to IEC 62053-23 Class C active energy conforming to EN 50470-3
This spec is not available in the specification table.
Network Frequency
60 Hz 50 Hz
This spec is not available in the specification table.
Sampling rate
32 samples/cycle
This spec is not available in the specification table.
Measurement current
0.02…1.2 A 0.05…6 A
This spec is not available in the specification table.
Communication Port Protocol
Modbus at 9.6...38.4 kbauds
This spec is not available in the specification table.
Communication port support
RS485
This spec is not available in the specification table.
Number of inputs
2 digital 0...4 mA 11...40 V DC
This spec is not available in the specification table.
Number of outputs
2 digital (static)
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1 (safety) CE conforming to EN 61557-12 (power monitor) CE conforming to EN/IEC 61326-1 (EMC) UKCA conforming to BS EN 61010-1 (safety) UKCA conforming to BS EN 61557-12 (power monitor) UKCA conforming to BS EN 61326-1 (EMC) CULus conforming to EN 61010-1 (safety) CULus conforming to UL 61010-1 (safety) EAC (sub-meter) RCM
This spec is not available in the specification table.
IP Degree of Protection
IP40 front panel: conforming to IEC 60529 IP20 body: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
< 3000 m
This spec is not available in the specification table.
Power quality analysis
up to the 15th harmonic
This spec is not available in the specification table.
supply voltage
100...277 V AC 45...65 Hz 173...480 V AC 45...65 Hz 100...300 V DC
This spec is not available in the specification table.
type of network
3P 3P + N 1P + N
This spec is not available in the specification table.
Display resolution
128 x 96 pixels
This spec is not available in the specification table.
Analogue input type
Current 0...5 A Current 0...1 A
This spec is not available in the specification table.
Measurement voltage
50…330 V AC 45...65 Hz direct 50…330 V AC 45...65 Hz phase to neutral 80…570 V AC 45...65 Hz direct 80…570 V AC 45...65 Hz phase to phase 570…999000 V AC 45...65 Hz with external VT
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Measurement accuracy
Current 0.3 % 0.5...6 A Current 0.5 % 0.1...1.2 A Voltage 0.3 % 50...330 V Voltage 0.3 % 80...570 V
This spec is not available in the specification table.
data recording
Energy consumption logs 15 alarms Power logs Time stamping Min/max of instantaneous values
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge level 4 conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Surge immunity test level 4 conforming to IEC 61000-4-5 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022
This spec is not available in the specification table.
Information displayed
Tariff (4)
This spec is not available in the specification table.
memory capacity
512 KB
This spec is not available in the specification table.
Power consumption in VA
5 VA
This spec is not available in the specification table.
Product Description

Schneider Electric METSEPM3255 2 Digital I - PM3255 Power Meter

PM3255 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. Support for two digital input and two digital outputs. The meter offers 512kB of memory for event recording with up to 15 alarms with power and energy consumption logs. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).

US $ 823.79
Quantity:
EA
This item is sold by
Image
MY-1270830467
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
23 Items
power-energy-meters-img
Poles Description
3P 1P + N 3P + N, 3P + N 1P + N 3P, 1P + N 3P 3P + N, 3P 3P + N 1P + N, 3P + N 3P 1P + N
[In] Rated Current
1 A 5 A, 125 A, 63 A, 1 A 5 A 10 A, 5 A 1 A
Type of Measurement
Active energy Current Voltage Active power, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms, Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total, Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Apparent energy total Active and reactive energy total Apparent power total Active and reactive power total Current average Voltage average Frequency average Power factor average
Display Type
Monochrome graphic LCD, Colour TFT LCD, 7 segments LED, Backlit LCD, TFT LCD
Standards
IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-24 EN 50470-3 IEC 62053-22:2020 IEC 61557-12:2015 ANSI C12.20 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-1 IEC 62053-24 IEC 60529 UL 61010-1 IEC 62053-22:2020 EN 50470-3 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, UL 61010-1 EN 50470-3 EN 50470-1 IEC 62053-22:2020 IEC 60529 IEC 62053-24 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
Ambient Air Temperature for Operation
-25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display, -25…55 °C - MID -25…70 °C - IEC -25…60 °C - IEC, -25…70 °C - IEC, -10…60 °C, -25…70 °C
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image