UL 508
EN/IEC 60947-5-5
CSA C22.2 No 14
EN/IEC 60947-5-1
JIS C8201-5-1
EN/IEC 60947-5-4
EN/IEC 60947-1
JIS C8201-1
Ip Degree Of Protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP69 conforming to IEC 60529
IP69K conforming to ISO 20653
Ambient Air Temperature For Operation
-40…70 °C
Ambient Air Temperature For Storage
-40…70 °C
Electrical Composition Code
P1 in front mounting with integral LED
P2 in front mounting with integral LED and transformer
PF1 in front mounting with integral LED
PR1 in rear mounting with integral LED
Mounting Diameter
22 mm
Shape Of Signaling Unit Head
Round
Cap/Operator Or Lens Colour
Blue
Bezel Material
Dark grey plastic
Device Short Name
ZB5
This spec is not available in the specification table.
Product Or Component Type
Head for pilot light
This spec is not available in the specification table.
Overvoltage Category
Class II conforming to IEC 60536
This spec is not available in the specification table.
Device Presentation
Basic element
This spec is not available in the specification table.
Ik Degree Of Protection
IK05 conforming to IEC 50102
This spec is not available in the specification table.
Product Compatibility
Universal LED
This spec is not available in the specification table.
Shock Resistance
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
This spec is not available in the specification table.
Resistance To High Pressure Washer
7000000 Pa at 55 °C, distance : 0.1 m
This spec is not available in the specification table.
Protective Treatment
TH
This spec is not available in the specification table.
Nema Degree Of Protection
NEMA 13
NEMA 4X
This spec is not available in the specification table.
Operator Additional Information
With plain lens
This spec is not available in the specification table.
Head Type
Standard
This spec is not available in the specification table.
Station Name
XALD 1...5 cut-outs
XALK 2...5 cut-outs
This spec is not available in the specification table.