Specifications:
Operating principle
Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.
Voltage sensing ranges
Nominally, 90 V AC to 1000 V AC 45 Hz to 405 Hz;
Detector tip style
Blade or round, depending on model
Light source
One high intensity red LED
Agency Approvals
c CSA us, CE, C-Tick
Safety Rating
1000 V, CAT IV
IP Rating
IP 40
Operating Temperature
-10 °C to 50 °C
Operating humidity ranges
0 % to 95 % --- (0 °C to 30 °C)
0 % to 75 % --- (30 °C to 40 °C)
0 % to 45 % --- (40 °C to 55 °C)
Operating Altitude
3000 meters
Batteries
2 AAA alkaline batteries included