High Accuracy, High Performance and Reliable Measurements
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Wide AC Frequency bandwidth from 10Hz to 100kHz
• True-RMS or MEAN value detection mode can be selected
• Fast Peak Hold response time of 250µs
• Low-pass filter for motor drive measurements
• Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V, CAT III 1000V
• Terminal shutter to prevent incorrect test leads’ insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
• Large data internal memory
KEW 1062: 10,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.