• Capable of measuring AC and DC currents up to 100A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
DC V
340mV/3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±4dgt
AC V
3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±5dgt [50 – 400Hz]
DC A
100A ±2%rdg±5dgt
AC A
100A ±2%rdg±5dgt (50/60Hz)
Ω
340Ω/3.4/34/340kΩ/3.4/34MΩ
±1%rdg±3dgt (0 – 340kΩ)
±5%rdg±5dgt (3.4MΩ)
±15%rdg±5dgt (34MΩ)
CONTINUITY BUZZER
Buzzer sounds below 30±10Ω
(Continuity buzzer works on 340Ω range only)
FREQUENCY
(AC A) 3.4/10kHz ±0.1%rdg±1dgt
(AC V) 3.4/34/300kHz ±0.1%rdg±1dgt
(Input sensitivity Current: more than 25A, Voltage: more than 30V)
CONDUCTOR SIZE
Ø10mm max.
APPLICABLE STANDARDS
IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1
POWER SOURCE
R03 (DC 1.5V) × 2
* Continuous measuring time: approx. 45 hours
(Auto power save: approx. 10 minutes)
DIMENSIONS
128(L) × 91(W) × 27(D)mm
WEIGHT
220g approx
INCLUDED ACCESSORIES
R03 (DC 1.5V) × 2,
Instruction Manual