Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric ATV320D15N4B Variable Speed Drive, Altivar Machine ATV320, 15kW, 380 to 500V, 3 Phases, Book
Schneider Electric ATV320D15N4B Variable Speed Drive, Altivar Machine ATV320, 15kW, 380 to 500V, 3 Phases, Book
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Inverter Drives dimensions or variations
Please select at least one specification below.
Range of Product
Altivar Machine ATV320
Mounting Mode
Wall mount
Standard
IEC 61800-5-1
IP Degree of Protection
IP20
Ambient Air Temperature for Operation
-10…50 °C without derating 50…60 °C with derating factor
Ambient Air Temperature for Storage
-25…70 °C
[Us] Rated Supply Voltage
380...500 V - 15...10 %
Switching Frequency
2...16 kHz adjustable 4...16 kHz with derating factor
Power Dissipation in W
Fan: 452.0 W at 380 V, switching frequency 4 kHz
Line Current
47.3 A at 380 V (heavy duty) 33.3 A at 500 V (heavy duty)
Apparent Power
28.8 kVA at 500 V (heavy duty)
Maximum Input Current
47.3 A
Maximum Output Voltage
500 V
Nominal Output Current
33.0 A
Width
180 mm
This spec is not available in the specification table.
Product or Component Type
Variable speed drive
This spec is not available in the specification table.
Depth
232.0 mm
This spec is not available in the specification table.
Height
404.0 mm
This spec is not available in the specification table.
Network Frequency
50...60 Hz
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Marking
CE ATEX UL CSA EAC RCM
This spec is not available in the specification table.
Analog Input Type
AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
This spec is not available in the specification table.
Motor Power kW
15.0 kW for heavy duty
This spec is not available in the specification table.
Minimum Switching Current
Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
This spec is not available in the specification table.
Certifications
CE ATEX NOM GOST EAC RCM KC
This spec is not available in the specification table.
Operating Position
Vertical +/- 10 degree
This spec is not available in the specification table.
Product Specific Application
Complex machines
This spec is not available in the specification table.
Protection Type
Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive
This spec is not available in the specification table.
Discrete Input Number
7
This spec is not available in the specification table.
Analogue Input Number
3
This spec is not available in the specification table.
Maximum Switching Current
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
This spec is not available in the specification table.
Discrete Input Logic
Positive logic (source) Negative logic (sink)
This spec is not available in the specification table.
Discrete Output Number
3
This spec is not available in the specification table.
Regulation Loop
Adjustable PID regulator
This spec is not available in the specification table.
Maximum Output Frequency
0.599 kHz
This spec is not available in the specification table.
Analogue Output Number
1
This spec is not available in the specification table.
Analogue Output Type
Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
This spec is not available in the specification table.
EMC Filter
Class C3 EMC filter integrated
This spec is not available in the specification table.
Method of Access
Slave CANopen
This spec is not available in the specification table.
Communication Port Protocol
Modbus serial CANopen
This spec is not available in the specification table.
Variant
Standard version
This spec is not available in the specification table.
Asynchronous Motor Control Profile
Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
This spec is not available in the specification table.
Synchronous Motor Control Profile
Vector control without sensor
This spec is not available in the specification table.
Nominal Switching Frequency
4 kHz
This spec is not available in the specification table.
Prospective Line Isc
22 kA
This spec is not available in the specification table.
Discrete Input Type
STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1...DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
This spec is not available in the specification table.
Discrete Output Type
Open collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA
This spec is not available in the specification table.
Relay Output Type
Configurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C
This spec is not available in the specification table.
4 Quadrant Operation Possible
True
This spec is not available in the specification table.
Acceleration and Deceleration Ramps
Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection
This spec is not available in the specification table.
Motor Slip Compensation
Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points)
This spec is not available in the specification table.
Braking to Standstill
By DC injection
This spec is not available in the specification table.
Brake Chopper Integrated
True
This spec is not available in the specification table.
Relative Symmetric Network Frequency Tolerance
5 %
This spec is not available in the specification table.
Base Load Current at High Overload
4 A
This spec is not available in the specification table.
With Safety Function Safely Limited Speed (SLS)
True
This spec is not available in the specification table.
With Safety Function Safe Brake Management (SBC/SBT)
False
This spec is not available in the specification table.
With Safety Function Safe Operating Stop (SOS)
False
This spec is not available in the specification table.
With Safety function Safe Position (SP)
False
This spec is not available in the specification table.
With Safety Function Safe Programmable Logic
False
This spec is not available in the specification table.
With Safety Function Safe Speed Monitor (SSM)
False
This spec is not available in the specification table.
With Safety Function Safe Stop 1 (SS1)
True
This spec is not available in the specification table.
With sft fct Safe Stop 2 (SS2)
False
This spec is not available in the specification table.
With Safety Function Safe Torque Off (STO)
True
This spec is not available in the specification table.
With Safety Function Safely Limited Position (SLP)
False
This spec is not available in the specification table.
With Safety Function Safe Direction (SDI)
False
This spec is not available in the specification table.
Environmental Class (During Operation)
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
This spec is not available in the specification table.
Maximum Acceleration Under Shock Impact (During Operation)
150 m/s² at 11 ms
This spec is not available in the specification table.
Maximum Acceleration Under Vibrational Stress (During Operation)
10 m/s² at 13...200 Hz
This spec is not available in the specification table.
Maximum Deflection Under Vibratory Load (During Operation)
1.5 mm at 2...13 Hz
This spec is not available in the specification table.
Permitted Relative Humidity (During Operation)
Class 3K5 according to EN 60721-3
This spec is not available in the specification table.
Volume of Cooling Air
156.0 m3/h
This spec is not available in the specification table.
Ambient Air Transport Temperature
-25…70 °C
This spec is not available in the specification table.
Option Card
Communication module, CANopen Communication module, EtherCAT Communication module, Profibus DP V1 Communication module, PROFINET Communication module, Ethernet Powerlink Communication module, EtherNet/IP Communication module, DeviceNet
This spec is not available in the specification table.
Format of the Drive
Book
This spec is not available in the specification table.
Transient Overtorque
170…200 % of nominal motor torque
This spec is not available in the specification table.
Speed Accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
This spec is not available in the specification table.
Product Description
RM 19,895.00
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Inverter Drives
13 Items
inverter-drives-img
Local Signalling
1 LED (red) for DC bus energized, Local diagnostic: 3 LED (mono/dual colour) Embedded communication status: 5 LED (dual colour) Communication module status: 2 LED (dual colour) Presence of voltage: 1 LED (red), 3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage 3 LEDs for local diagnostic
Range of Product
Altivar Machine ATV320, Altivar Process ATV900, Altivar 12, Easy Altivar 310, Altivar 212
Mounting Mode
Wall mount, Cabinet mount, Wall Mount, DIN Rail, Cabinet Mount
Standard
IEC 61800-3 category C3 IEC 61800-3 category C2 EN 61800-3 category C3 EN 55011 class A group 1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 2 category C2 IEC 61800-3 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-5-1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-5-1 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 UL Type 1, CE, CSA, UL, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, NOM 117, RCM, UL, ATEX, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, TUV, UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 13849-1, IEC 60721-3, IEC 61000-3-12, IEC 61508, UL 508C
IP Degree of Protection
IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529, IP20 without blanking plate on upper part IP40 top, IP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1, IP55, IP54
Ambient Air Temperature for Operation
-10…50 °C without derating 50…60 °C with derating factor, -10…40 °C without derating 40…60 °C with current derating 2.2 % per °C, -10…55 °C without derating 55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C, 40…50 °C (with derating factor) -15…40 °C (without derating), -10…40 °C (without derating) 40…50 °C (with derating factor)
Operating Altitude
<= 1000 m without derating, 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating, > 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating, <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m, 1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Inverter Drives from SCHNEIDER ELECTRIC
Source & compare similar products
More from Inverter Drives
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image