Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric EZC100N3060 Circuit Breaker Easypact EZC100N - Tmd - 60 a - 3 Poles 3d
Schneider Electric EZC100N3060 Circuit Breaker Easypact EZC100N - Tmd - 60 a - 3 Poles 3d
Image
Image
Specifications
infotip-icon
View other Circuit Breaker dimensions or variations
Please select at least one specification below.
Ambient air temperature for operation
-25…70 °C
Poles Description
3P
Protected Poles Description
3t
Network Type
AC DC
[In] Rated Current
60 A at 40 °C
Network Frequency
50/60 Hz
Standards
EN/IEC 60947-1 JIS C8201-2-2 GB/T 14048.2 EN/IEC 60947-2
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-2
Ip Degree Of Protection
IP20 conforming to IEC 60529
Pollution Degree
3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Ambient Air Temperature For Storage
-35…85 °C
[Ue] Rated Operational Voltage
550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Trip Unit Rating
60 A at 50 °C
Breaking Capacity
10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Trip Unit Technology
Thermal-magnetic
This spec is not available in the specification table.
Control Type
Toggle
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Trip Unit Name
TM-D
This spec is not available in the specification table.
Device Short Name
Easypact EZC100N
This spec is not available in the specification table.
Product Or Component Type
Circuit breaker
This spec is not available in the specification table.
Range Of Product
EasyPact
This spec is not available in the specification table.
Device Application
Distribution
This spec is not available in the specification table.
Connection Pitch
25 mm
This spec is not available in the specification table.
Utilisation Category
Category A
This spec is not available in the specification table.
Suitability For Isolation
Yes conforming to IEC 60947-2
This spec is not available in the specification table.
Mounting Support
Backplate
This spec is not available in the specification table.
Local Signalling
Positive contact indication
This spec is not available in the specification table.
Mechanical Durability
8500 cycles
This spec is not available in the specification table.
Electrical Durability
Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Earth-Leakage Protection
Without
This spec is not available in the specification table.
Ik Degree Of Protection
IK07 conforming to IEC 62262
This spec is not available in the specification table.
Protection Type
Overload protection Short-circuit protection
This spec is not available in the specification table.
Upside Connection
Front
This spec is not available in the specification table.
Downside Connection
Front
This spec is not available in the specification table.
Depth
60 mm
This spec is not available in the specification table.
[Ics] Rated Service Breaking Capacity
5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Height
130 mm
This spec is not available in the specification table.
Breaking Capacity Code
N
This spec is not available in the specification table.
Circuit Breaker Name
Easypact EZC100N
This spec is not available in the specification table.
Neutral Protection Setting
Without protection
This spec is not available in the specification table.
Product Description

Schneider Electric EZC100N3060 Circuit Breaker,easypact EZC100N ,tmd, 60A ,3 Poles 3d

EasyPact EZC100N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 15kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 60A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100N is compliant with international standards (IEC 60947, UL 508) and marine certifications.

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Circuit Breaker from SCHNEIDER ELECTRIC
Source & compare similar products
More from Circuit Breaker
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image