Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric LADN04 Auxiliary Contact Block, Tesys Deca, 4NC, Front Mounting, Screw Clamp Terminals
Schneider Electric LADN04 Auxiliary Contact Block, Tesys Deca, 4NC, Front Mounting, Screw Clamp Terminals
Image
Image
Specifications
infotip-icon
View other Auxiliary Contact dimensions or variations
Please select at least one specification below.
Rated Current
6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
Colour
Dark grey
Range
TeSys TeSys Deca
Standard
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-5-1 600 V conforming to UL 600 V conforming to CSA
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-5…60 °C
Ambient Air Temperature for Storage
-60…80 °C
[Ue] Rated Operational Voltage
690 V AC 25...400 Hz
Pole contact composition
4 NC
Width
44 mm
This spec is not available in the specification table.
Device Short Name
LADN
This spec is not available in the specification table.
Product Name
TeSys Deca
This spec is not available in the specification table.
Depth
42 mm
This spec is not available in the specification table.
Connections - Terminals
Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable end
This spec is not available in the specification table.
Product certifications
CB UL CSA CCC EAC UKCA
This spec is not available in the specification table.
Height
48 mm
This spec is not available in the specification table.
Mechanical Durability
30 Mcycles
This spec is not available in the specification table.
Operating Altitude
3000 m
This spec is not available in the specification table.
Tightening Torque
1.7 N.m - with screwdriver flat Ø 6 mm 1.7 N.m - with screwdriver Philips No 2 1.7 N.m - with screwdriver pozidriv No 2
This spec is not available in the specification table.
Environmental Characteristic
Normal environment
This spec is not available in the specification table.
[Ith] conventional free air thermal current
10 A (at 60 °C)
This spec is not available in the specification table.
Irms rated making capacity
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
This spec is not available in the specification table.
Minimum switching voltage
17 V
This spec is not available in the specification table.
Minimum Switching Current
5 mA
This spec is not available in the specification table.
Insulation Resistance
> 10 MOhm
This spec is not available in the specification table.
Non-overlap time
1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068
This spec is not available in the specification table.
Range compatibility
TeSys D LC1D TeSys D CAD TeSys F LC1F TeSys F CR1F TeSys Deca CAD TeSys Deca LC1D
This spec is not available in the specification table.
Permissible short-time rating
100 A 1 s 120 A 500 ms 140 A 100 ms
This spec is not available in the specification table.
Protection type
GG fuse 10 A
This spec is not available in the specification table.
Mounting location
Front
This spec is not available in the specification table.
Contacts operation
Instantaneous
This spec is not available in the specification table.
Product Description
RM 143.00
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
35 Items
auxiliary-contact-img
Rated Current
AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
Range
Acti9, EasyPact, TeSys, TeSys TeSys Deca, Tesys
Standard
UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 EN 50012, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012
[Ui] Rated Insulation Voltage
500 V, 690 V conforming to IEC 60947-5-1 600 V conforming to UL 600 V conforming to CSA, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14, 250 V conforming to CSA 250 V conforming to IEC 60947-5-1 250 V conforming to UL
Ambient Air Temperature for Operation
-25…60 °C, -35…70 °C, -20…50 °C, -25…50 °C, -5…60 °C
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz, 24...240 V AC 24...60 V DC, 48...690 V AC 24...240 V DC, 690 V AC 25...400 Hz, <= 250 V AC <= 250 V DC
Pole contact composition
2 NO + 2 NC, 4 NC, 1 NO + 3 NC, 2 NO, 3 NO + 1 NC
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image