Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric LR3D086 Tesys Lrd Thermal Overload Relays - 2.5...4 a - Class 10A
Schneider Electric LR3D086 Tesys Lrd Thermal Overload Relays - 2.5...4 a - Class 10A
Image
Image
Specifications
infotip-icon
View other Overload Relays dimensions or variations
Please select at least one specification below.
Ambient Air Temperature For Operation
-20 → +60 °C
[Us] Rated Supply Voltage
690 V ac
Range
TeSys
This spec is not available in the specification table.
Connections - Terminals
Screw
This spec is not available in the specification table.
Width
70 mm
This spec is not available in the specification table.
Series
LR3D
This spec is not available in the specification table.
Length
45 mm
This spec is not available in the specification table.
Minimum Operating Temperature
-20°C
This spec is not available in the specification table.
Maximum Operating Temperature
+60°C
This spec is not available in the specification table.
Reset Method
Push Button
This spec is not available in the specification table.
Contact Current Rating
4 A
This spec is not available in the specification table.
Better World Product
Yes
This spec is not available in the specification table.
Better World Verification
Green Premium
This spec is not available in the specification table.
Product Description
RM 520.50
(exc. SST)
RM 551.73
(inc. SST)
Quantity:
EA
This item is sold by
Image
MY-2155714050
Shop by Specification Table
You can find items with similar specifications from the table below.
Overload Relays
53 Items
overload-relays-img
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5, IEC 60255-17 IEC 60947-4-1 IEC 60255-8 VDE 0660 EN 60947-4-1, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
[Ui] Rated Insulation Voltage
Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC conforming to UL Power circuit: 690 V AC conforming to IEC 60947-4-1, Power circuit: 1000 V AC conforming to IEC 60947-4, Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1, Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL, Power circuit: 1000 V conforming to IEC 60947-4-1
Ambient Air Temperature For Operation
-20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947, -20…55 °C conforming to IEC 60255-8, -20…60 °C without derating conforming to IEC 60947-4-1, -25 → +60 °C, -20 → +60 °C
[Ith] Conventional Free Air Thermal Current
6 A for signalling circuit, 3 A for signalling circuit, 5 A for signalling circuit, 3 A for control circuit, 5 A for control circuit
Thermal Protection Adjustment Range
80…104 A, 30…40 A, 30…38 A, 48…65 A, 110…140 A
[Us] Rated Supply Voltage
100...120 V AC, 200...240 V AC, 24 V DC, 24 V ac/dc, 690 V ac
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Overload Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Overload Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image