Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric LR97D07M7 Electronic Overcurrent Relay, Tesys LR97D, 200 to 240VAC, 1.2 to 7A, 1C/O
Schneider Electric LR97D07M7 Electronic Overcurrent Relay, Tesys LR97D, 200 to 240VAC, 1.2 to 7A, 1C/O
Image
Image
Specifications
infotip-icon
View other Overload Relays dimensions or variations
Please select at least one specification below.
Network Type
AC
Network Frequency
50...60 Hz
Standards
IEC 60947 IEC 60255-6
[Ui] Rated Insulation Voltage
Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage
6 kV
Ambient Air Temperature For Operation
-25…60 °C conforming to IEC 60947-4-1
Ambient Air Temperature For Storage
-30…80 °C
[Ith] Conventional Free Air Thermal Current
3 A for control circuit
Thermal Protection Adjustment Range
1.2…7 A
[Us] Rated Supply Voltage
200...240 V AC
Device Short Name
LR97
This spec is not available in the specification table.
Product Or Component Type
Electronic overcurrent relay
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys D
This spec is not available in the specification table.
Mounting Support
Direct on contactor Rail
This spec is not available in the specification table.
Connections - Terminals
Control circuit: cable 1 x 1…25 mm²flexible with cable end Control circuit: cable 1 x 1…25 mm²flexible without cable end Power circuit: cable 1 x 1…4 mm²flexible with cable end Power circuit: cable 1 x 1.5…10 mm²flexible without cable end Power circuit: lug-clamp 1 x 1…4 mm²flexible with cable end Power circuit: lug-clamp 1 x 1.5…10 mm²flexible without cable end Control circuit: cable 2 x 1…25 mm²flexible with cable end Control circuit: cable 2 x 1…25 mm²flexible without cable end Control circuit: lug-clamp 1 x 1…25 mm²flexible with cable end Control circuit: lug-clamp 1 x 1…25 mm²flexible without cable end Control circuit: lug-clamp 2 x 1…25 mm²flexible with cable end Control circuit: lug-clamp 2 x 1…25 mm²flexible without cable end
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 conforming to IEC 60529
This spec is not available in the specification table.
Operating Altitude
2000 m
This spec is not available in the specification table.
Tightening Torque
Control circuit: 0.6...1.2 N.m on lug-clamp Power circuit: 2 N.m on cable
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
600 V AC 50/60 Hz for power circuit conforming to CSA 600 V AC 50/60 Hz for power circuit conforming to UL 690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1
This spec is not available in the specification table.
Product Certifications
GOST CSA UL
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068
This spec is not available in the specification table.
Fire Resistance
850 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Phase Failure Sensitivity
< 3 s
This spec is not available in the specification table.
Contacts Type And Composition
1 C/O
This spec is not available in the specification table.
Product Compatibility
LC1D09...D38
This spec is not available in the specification table.
Tripping Threshold
1.2...6 A
This spec is not available in the specification table.
Relay Application
Sensitivity to phase failure Locked rotor, mechanical jamming I > 3 x Isetting Overload Imax > Isetting
This spec is not available in the specification table.
Signalling Function
2 LEDs
This spec is not available in the specification table.
Dielectric Strength
2 V 50 Hz conforming to IEC 60255-5
This spec is not available in the specification table.
Surge Withstand
6 kV conforming to IEC 61000-4-5
This spec is not available in the specification table.
Reset
Automatic reset 120 s fixed Electrical by interruption of power supply for minimum 0.1 s Manual reset
This spec is not available in the specification table.
Time Range
0.2...10 s - O-time knob 0.3...10 s - O-time knob 0.5..30 s - D-time knob
This spec is not available in the specification table.
Shock Resistance
15 gn 11 ms conforming to IEC 60068-2-7
This spec is not available in the specification table.
Vibration Resistance
4 gn conforming to IEC 60068-2-6
This spec is not available in the specification table.
Resistance To Electrostatic Discharge
6 kV in indirect mode 8 kV in air
This spec is not available in the specification table.
Resistance To Radiated Fields
10 V/m level 3
This spec is not available in the specification table.
Resistance To Fast Transients
2 kV
This spec is not available in the specification table.
Protection Type
BS fuse 3 A - for control circuit GB2 circuit breaker 3 A - for control circuit GG fuse 3 A - for control circuit
This spec is not available in the specification table.
Disturbance Radiated/Conducted
10 V conforming to EN 61000-4-6 Class A conforming to EN 55011
This spec is not available in the specification table.
Maximum Power
28 W at 110 V DC conforming to IEC 60947 28 W at 220 V DC conforming to IEC 60947 55 W at 24 V DC conforming to IEC 60947 55 W at 48 V DC conforming to IEC 60947 140 VA at 48 V AC conforming to IEC 60947 360 VA at 110 V AC conforming to IEC 60947 360 VA at 220 V AC conforming to IEC 60947 70 VA at 24 V AC conforming to IEC 60947
This spec is not available in the specification table.
Product Description
RM 583.50
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Overload Relays
53 Items
overload-relays-img
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5, IEC 60255-17 IEC 60947-4-1 IEC 60255-8 VDE 0660 EN 60947-4-1, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
[Ui] Rated Insulation Voltage
Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC conforming to UL Power circuit: 690 V AC conforming to IEC 60947-4-1, Power circuit: 1000 V AC conforming to IEC 60947-4, Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1, Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL, Power circuit: 1000 V conforming to IEC 60947-4-1
Ambient Air Temperature For Operation
-20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947, -20…55 °C conforming to IEC 60255-8, -20…60 °C without derating conforming to IEC 60947-4-1, -25 → +60 °C, -20 → +60 °C
[Ith] Conventional Free Air Thermal Current
6 A for signalling circuit, 3 A for signalling circuit, 5 A for signalling circuit, 3 A for control circuit, 5 A for control circuit
Thermal Protection Adjustment Range
80…104 A, 30…40 A, 30…38 A, 48…65 A, 110…140 A
[Us] Rated Supply Voltage
100...120 V AC, 200...240 V AC, 24 V DC, 24 V ac/dc, 690 V ac
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Overload Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Overload Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image