Schneider Electric LRD08 Thermal Overload Relay, Tesys Deca, 690VAC, 3P, 2.5 to 4A, 1NO+1NC, Class 10A, Screw Clamp
Schneider Electric LRD08 Thermal Overload Relay, Tesys Deca, 690VAC, 3P, 2.5 to 4A, 1NO+1NC, Class 10A, Screw Clamp
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Overload Relays dimensions or variations
Please select at least one specification below.
Network Type
AC DC
Network Frequency
0...400 Hz
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
[Ui] Rated Insulation Voltage
Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage
6 kV
Ambient Air Temperature For Operation
-20…60 °C without derating conforming to IEC 60947-4-1
Ambient Air Temperature For Storage
-60…70 °C
[Ith] Conventional Free Air Thermal Current
5 A for signalling circuit
Auxiliary Contact Composition
1 NO + 1 NC
Thermal Protection Adjustment Range
2.5…4 A
Control Type
Red push-button: stop Blue push-button: reset
This spec is not available in the specification table.
Device Short Name
LRD
This spec is not available in the specification table.
Product Or Component Type
Differential thermal overload relay
This spec is not available in the specification table.
Range
TeSys TeSys Deca
This spec is not available in the specification table.
Product Name
TeSys LRD TeSys Deca
This spec is not available in the specification table.
Mounting Support
Plate, with specific accessories Rail, with specific accessories Under contactor
This spec is not available in the specification table.
Connections - Terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable end
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 conforming to IEC 60529
This spec is not available in the specification table.
Tightening Torque
Control circuit: 1.7 N.m - on screw clamp terminals Power circuit: 1.7 N.m - on screw clamp terminals
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
This spec is not available in the specification table.
Associated Fuse Rating
4 A gG for signalling circuit 4 A BS for signalling circuit
This spec is not available in the specification table.
Product Certifications
IEC UL CSA CCC EAC BV RINA DNV-GL LROS (Lloyds register of shipping) ATEX INERIS UKCA
This spec is not available in the specification table.
Mechanical Robustness
Vibrations: 6 Gn conforming to IEC 60068-2-6 Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
This spec is not available in the specification table.
Phase Failure Sensitivity
Tripping current 130 % of Ir on two phase, the last one at 0
This spec is not available in the specification table.
Product Compatibility
LC1D12 LC1D09 LC1D25 LC1D38 LC1D32 LC1D18
This spec is not available in the specification table.
Tripping Threshold
1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
This spec is not available in the specification table.
Relay Application
Motor protection
This spec is not available in the specification table.
Dielectric Strength
1.89 kV at 50 Hz conforming to IEC 60947-1
This spec is not available in the specification table.
Climatic Withstand
conforming to IACS E10
This spec is not available in the specification table.
Flame Retardance
V1 conforming to UL 94
This spec is not available in the specification table.
Thermal Overload Class
Class 10A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Temperature Compensation
-20…60 °C
This spec is not available in the specification table.
Permissible Current
3 A at 120 V AC-15 for signalling circuit 0.22 A at 125 V DC-13 for signalling circuit
This spec is not available in the specification table.
Product Description
RM 229.00
(exc. SST)
RM 242.74
(inc. SST)
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Overload Relays
53 Items
overload-relays-img
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5, IEC 60255-17 IEC 60947-4-1 IEC 60255-8 VDE 0660 EN 60947-4-1, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
[Ui] Rated Insulation Voltage
Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC conforming to UL Power circuit: 690 V AC conforming to IEC 60947-4-1, Power circuit: 1000 V AC conforming to IEC 60947-4, Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1, Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL, Power circuit: 1000 V conforming to IEC 60947-4-1
Ambient Air Temperature For Operation
-20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947, -20…55 °C conforming to IEC 60255-8, -20…60 °C without derating conforming to IEC 60947-4-1, -25 → +60 °C, -20 → +60 °C
[Ith] Conventional Free Air Thermal Current
6 A for signalling circuit, 3 A for signalling circuit, 5 A for signalling circuit, 3 A for control circuit, 5 A for control circuit
Thermal Protection Adjustment Range
80…104 A, 30…40 A, 30…38 A, 48…65 A, 110…140 A
[Us] Rated Supply Voltage
100...120 V AC, 200...240 V AC, 24 V DC, 24 V ac/dc, 690 V ac
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Overload Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Overload Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image