Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric LUA1C11 Signalling Contacts Lua - 1 No + 1 Nc
Schneider Electric LUA1C11 Signalling Contacts Lua - 1 No + 1 Nc
Image
Image
Specifications
infotip-icon
View other Auxiliary Contact dimensions or variations
Please select at least one specification below.
Range
TeSys
[Ui] Rated Insulation Voltage
250 V conforming to CSA 250 V conforming to IEC 60947-5-1 250 V conforming to UL
[Ue] Rated Operational Voltage
<= 250 V AC <= 250 V DC
Device Short Name
LUA1
This spec is not available in the specification table.
Connections - Terminals
Screw clamp terminals
This spec is not available in the specification table.
[Ith] conventional free air thermal current
2.5 A
This spec is not available in the specification table.
Auxiliary contact composition
1 NO + 1 NC
This spec is not available in the specification table.
Minimum switching voltage
17 V
This spec is not available in the specification table.
Minimum Switching Current
5 mA
This spec is not available in the specification table.
Signalling function
Fault signalling Indicating rotary knob in ready position
This spec is not available in the specification table.
Product Description

Schneider Electric LUA1C11 Auxiliary Contact, Tesys Ultra, 1NO + 1NC, 0 to 250VAC/DC, for Fault Signalling

TeSys U auxiliary signaling contact block for TeSys U starter controllers. It provides 1NO contact for open/close status (OF contact) and 1NC contact for tripping status (SD contact), rated up to 5A 250V AC/DC. To be inserted in the provided location of the power base. Green Premium compliant (RoHS/REACh).

RM 132.50
Quantity:
EA
This item is sold by
Image
MY-2155714050
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
35 Items
auxiliary-contact-img
Rated Current
AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
Range
Acti9, EasyPact, TeSys, TeSys TeSys Deca, Tesys
Standard
UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 EN 50012, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012
[Ui] Rated Insulation Voltage
500 V, 690 V conforming to IEC 60947-5-1 600 V conforming to UL 600 V conforming to CSA, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14, 250 V conforming to CSA 250 V conforming to IEC 60947-5-1 250 V conforming to UL
Ambient Air Temperature for Operation
-25…60 °C, -35…70 °C, -20…50 °C, -25…50 °C, -5…60 °C
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz, 24...240 V AC 24...60 V DC, 48...690 V AC 24...240 V DC, 690 V AC 25...400 Hz, <= 250 V AC <= 250 V DC
Pole contact composition
2 NO + 2 NC, 4 NC, 1 NO + 3 NC, 2 NO, 3 NO + 1 NC
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image