Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric LUCB05FU Advanced Control Unit, Tesys Ultra, 3P, 1.25 to 5A, 690VAC, Protection & Diagnostic, Class 10, 110 to 240VAC/DC Coil
Schneider Electric LUCB05FU Advanced Control Unit, Tesys Ultra, 3P, 1.25 to 5A, 690VAC, Protection & Diagnostic, Class 10, 110 to 240VAC/DC Coil
Image
Image
Specifications
infotip-icon
View other Motor Starter dimensions or variations
Please select at least one specification below.
Rated Voltage
690 V AC
Operating Temperature
-25…70 °C
Standards and Certifications
EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Coil Voltage
110...240 V AC 110...220 V DC
Width
45 mm
Depth
60 mm
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-6-2
Ip Degree Of Protection
IP20 front panel and wired terminals conforming to IEC 60947-1 IP20 other faces conforming to IEC 60947-1 IP40 front panel outside connection zone conforming to IEC 60947-1
Height
66 mm
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys Ultra
This spec is not available in the specification table.
Device Short Name
LUCB
This spec is not available in the specification table.
Device Application
Motor control Motor protection
This spec is not available in the specification table.
Utilisation Category
AC-41 AC-44 AC-43
This spec is not available in the specification table.
Compatibility Code
LUCB
This spec is not available in the specification table.
Network Frequency
40...60 Hz
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
2000 m
This spec is not available in the specification table.
Fixing Mode
Plug-in (front face)
This spec is not available in the specification table.
Motor Power Kw
1.5 kW at 400...440 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz 3 kW at 690 V AC 50/60 Hz
This spec is not available in the specification table.
Control Circuit Voltage Limits
88...264 V for AC circuit 110...240 V in operation 88...242 V for DC circuit 110...220 V in operation 55 V for AC circuit 110...240 V drop-out 55 V for DC circuit 110...220 V drop-out
This spec is not available in the specification table.
Heat Dissipation
2 W for control circuit with LUB12 3 W for control circuit with LUB32 3 W for control circuit with LUB38
This spec is not available in the specification table.
Operating Time
35 ms opening with LUB12 for control circuit 35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 50 ms closing with LUB12 for control circuit 50 ms closing with LUB32 for control circuit 50 ms closing with LUB38 for control circuit
This spec is not available in the specification table.
Product Certifications
CE UL CSA CCC EAC ASEFA ATEX Marine
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068
This spec is not available in the specification table.
Fire Resistance
960 °C parts supporting live components conforming to IEC 60695-2-12 650 °C conforming to IEC 60695-2-12
This spec is not available in the specification table.
Phase Failure Sensitivity
Yes
This spec is not available in the specification table.
Product Specific Application
Basic protection and advanced functions, communication
This spec is not available in the specification table.
Product Compatibility
Power base LUB12 Power base LUB32 Power base LUB38 Power base LUB120 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B12FU Reversing contactor breaker LU2B32FU Reversing contactor breaker LU2B38FU
This spec is not available in the specification table.
Main Function Available
Protection against overload and short-circuit Earth fault protection Protection against phase failure and phase imbalance Manual reset
This spec is not available in the specification table.
Load Type
3-phase motor - cooling: self-cooled
This spec is not available in the specification table.
Rated Motor Current Adjustment Range
1.25…5 A
This spec is not available in the specification table.
Thermal Overload Class
Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2 Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
This spec is not available in the specification table.
Tripping Threshold
14.2 x Ir +/- 20 %
This spec is not available in the specification table.
Typical Current Consumption
280 mA at 110...240 V AC I maximum while closing with LUB12 280 mA at 110...240 V AC I maximum while closing with LUB32 280 mA at 110...240 V AC I maximum while closing with LUB38 280 mA at 110...220 V DC I maximum while closing with LUB12 280 mA at 110...220 V DC I maximum while closing with LUB32 280 mA at 110...220 V DC I maximum while closing with LUB38 35 mA at 110...240 V AC I rms sealed with LUB12 25 mA at 110...240 V AC I rms sealed with LUB32 25 mA at 110...240 V AC I rms sealed with LUB38 35 mA at 110...220 V DC I rms sealed with LUB12 25 mA at 110...220 V DC I rms sealed with LUB32 25 mA at 110...220 V DC I rms sealed with LUB38
This spec is not available in the specification table.
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
This spec is not available in the specification table.
Shock Resistance
10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
This spec is not available in the specification table.
Resistance To Electrostatic Discharge
8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2
This spec is not available in the specification table.
Non-Dissipating Shock Wave
1 kV serial mode conforming to IEC 60947-6-2 2 kV common mode conforming to IEC 60947-6-2
This spec is not available in the specification table.
Resistance To Radiated Fields
10 V/m 3 conforming to IEC 61000-4-3
This spec is not available in the specification table.
Resistance To Fast Transients
2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
This spec is not available in the specification table.
Immunity To Radioelectric Fields
10 V conforming to IEC 61000-4-6
This spec is not available in the specification table.
Immunity To Microbreaks
3 ms
This spec is not available in the specification table.
Immunity To Voltage Dips
70 % / 500 ms conforming to IEC 61000-4-11
This spec is not available in the specification table.
Reset
Manual reset
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Starter from SCHNEIDER ELECTRIC
Source & compare similar products
More from Motor Starter
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image