Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric METSEPM5650 Power Meter Powerlogic PM5650, 2 Ethernet, up to 63th Harmonic, 1,1MB, Waveform, 4DI/2DO 52 Alarms
Schneider Electric METSEPM5650 Power Meter Powerlogic PM5650, 2 Ethernet, up to 63th Harmonic, 1,1MB, Waveform, 4DI/2DO 52 Alarms
Image
Image
Specifications
infotip-icon
View other Power & Energy Meters dimensions or variations
Please select at least one specification below.
Range
PowerLogic
[In] Rated Current
1 A 5 A
Type of Measurement
Current Voltage Frequency Power factor Energy Active and reactive power
Display Type
Monochrome graphic LCD
Standards
EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015
Ambient Air Temperature for Operation
-25…70 °C
Width
96 mm
This spec is not available in the specification table.
Device Short Name
PM5650
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
PowerLogic PM5000
This spec is not available in the specification table.
Depth
72 mm
This spec is not available in the specification table.
Device Application
Gateway WAGES metering Power monitoring Multi-tariff
This spec is not available in the specification table.
Mounting Support
Framework
This spec is not available in the specification table.
Height
96 mm
This spec is not available in the specification table.
Mounting Mode
Flush-mounted
This spec is not available in the specification table.
Accuracy class
Class 0.2S active energy conforming to IEC 62053-22
This spec is not available in the specification table.
Network Frequency
60 Hz 50 Hz
This spec is not available in the specification table.
Sampling rate
128 samples/cycle
This spec is not available in the specification table.
Measurement current
50…10000 mA
This spec is not available in the specification table.
Communication Port Protocol
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V JBUS Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V Ethernet Modbus TCP/IP daisy chain BACnet IP DNP3 over ethernet
This spec is not available in the specification table.
Communication port support
RS485 ETHERNET
This spec is not available in the specification table.
Number of inputs
4 digital
This spec is not available in the specification table.
Number of outputs
2 digital
This spec is not available in the specification table.
Connections - Terminals
Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 RS485 link: screw terminal block4 Digital input: screw terminal block8 Digital output: screw terminal block4 Ethernet network: RJ45 connector2
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1 CULus conforming to UL 61010-1
This spec is not available in the specification table.
IP Degree of Protection
IP54 display: conforming to IEC 60529 IP30 rear: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C non-condensing
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
<= 3000 m
This spec is not available in the specification table.
Power quality analysis
up to the 63rd harmonic waveform capture voltage sag and swell detection
This spec is not available in the specification table.
supply voltage
100...300 V DC 90...528 V AC 45...65 Hz
This spec is not available in the specification table.
type of network
3P + N 3P 1P + N
This spec is not available in the specification table.
Maximum power consumption in VA
16 VA at 480 V
This spec is not available in the specification table.
Ride-through time
35 ms 120 V AC typical 129 ms 230 V AC typical 50 ms 125 V DC typical
This spec is not available in the specification table.
Display resolution
128 x 128 pixels
This spec is not available in the specification table.
Analogue input type
Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm)
This spec is not available in the specification table.
Measurement voltage
20…400 V AC 45...65 Hz between phase and neutral 20…828 V AC 45...65 Hz between phases
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Measurement accuracy
Apparent power +/- 0.5 % Frequency +/- 0.05 % Active energy +/- 0.2 % Reactive energy +/- 1 % Active power +/- 0.2 % Voltage +/- 0.1 % Power factor +/- 0.005 Current +/- 0.15 % Reactive power +/- 1 %
This spec is not available in the specification table.
data recording
Event logs Maintenance logs Min/max of instantaneous values Data logs Alarm logs Time stamping
This spec is not available in the specification table.
Electromagnetic Compatibility
Limits for harmonic current emissions class A conforming to IEC 61000-3-2 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency level 4 conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022 Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Surge immunity test level 4 conforming to IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
This spec is not available in the specification table.
Information displayed
Tariff (8)
This spec is not available in the specification table.
memory capacity
1.1 MB
This spec is not available in the specification table.
Metering type
Measured neutral current Calculated ground current
This spec is not available in the specification table.
Web services
Alarm notification by e-mail Web server Diagnostic via predefined web pages Real time viewing of data
This spec is not available in the specification table.
Ethernet service
SNTP client SNMP-Traps
This spec is not available in the specification table.
communication gateway
Ethernet/serial
This spec is not available in the specification table.
Product Description

Schneider Electric METSEPM5650 Power Meter Powerlogic PM5650, 2 Ethernet, up to 63th Harmonic, 1,1MB, Waveform, 4DI/2DO 52 Alarms

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic. Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration. This meter also feature the direct monitoring of neutral current plus an advanced waveform capture with sag and swell detection. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 480 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz. Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support. The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway. The meter also has four digital inputs with WAGES support and two digital outputs. There are 52 configurable alarms and it supports eight tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).

RM 14,665.00
Quantity:
EA
This item is sold by
Image
MY-1270830467
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
23 Items
power-energy-meters-img
Poles Description
3P 1P + N 3P + N, 3P + N 1P + N 3P, 1P + N 3P 3P + N, 3P 3P + N 1P + N, 3P + N 3P 1P + N
[In] Rated Current
1 A 5 A, 125 A, 63 A, 1 A 5 A 10 A, 5 A 1 A
Type of Measurement
Active energy Current Voltage Active power, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms, Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total, Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Apparent energy total Active and reactive energy total Apparent power total Active and reactive power total Current average Voltage average Frequency average Power factor average
Display Type
Monochrome graphic LCD, Colour TFT LCD, 7 segments LED, Backlit LCD, TFT LCD
Standards
IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-24 EN 50470-3 IEC 62053-22:2020 IEC 61557-12:2015 ANSI C12.20 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-1 IEC 62053-24 IEC 60529 UL 61010-1 IEC 62053-22:2020 EN 50470-3 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, UL 61010-1 EN 50470-3 EN 50470-1 IEC 62053-22:2020 IEC 60529 IEC 62053-24 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
Ambient Air Temperature for Operation
-25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display, -25…55 °C - MID -25…70 °C - IEC -25…60 °C - IEC, -25…70 °C - IEC, -10…60 °C, -25…70 °C
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image