• High Sensitive Model
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA.
AC A (50/60HZ)
4/40mA/100A
±1%rdg±5dgt (4/40mA)
±1%rdg±5dgt (0 – 80A)
±5%rdg (80.1 – 100A)
AC A (WIDE)
4/40mA/100A
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [20Hz – 1kHz] (4/40mA)
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [40Hz – 1kHz] (0 – 80A)
±5%rdg [50/60Hz],
±10%rdg [40Hz – 1kHz] (80.1 – 100A)
MAXIMUM CIRCUIT VOLTAGE
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
CONDUCTOR SIZE
Ø40mm max.
FREQUENCY RESPONSE
20Hz – 1kHz (40Hz – 1kHz:100A)
EFFECT OF EXTERNAL STRAY MAGNETIC FIELD
2mA AC approx. in proximity to a 15mm-dia conductor carrying 100A AC
SAFETY STANDARD
IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
RESPONSE TIME
Approx. 2 seconds
POWER SOURCE
Two R03 or equivalent (DC1.5V) batteries
DIMENSIONS
185(L) × 81(W) × 32(D)mm
WEIGHT
290g approx.
INCLUDED ACCESSORIES
9097 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual