• Extremely easy and simple operation
• Automatic ranges, indicated by individual LED’s
• Newly-designed alligator clip
• It comes with a tough hard case
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
Insulation Resistance
2500V
2GΩ/100GΩ (Auto-ranging)
0.1 – 50GΩ: ±5%rdg
0 – 0.1GΩ, 50GΩ – ∞:
±10%rdg or 0.5% of scale length
General
IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V
Pollution degree 2, IEC 61010-031, IEC 61326-1, 2-2
DC12V : LR14/R14 × 8pcs
177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Hard case)
7165A (Line probe: 3m)
7264 (Earth cord: 3m)
7265 (Guard cord: 3m)
8019 (Hook type prod)
9182 (Carrying case[Hard])
LR14 (Alkaline battery size C) × 8
Instruction manual