Specifications:
- Measuring Method: Dual slope integration mode
- Display: 3.5 digit LCD, max. reading of 3200
- Sampling:
- Digital display: 2 times/second
- Bar graph display: 12 times/second
- Low Battery Indication: Displays "Battery" mark on LCD
- Over Range Indication: Displays "OL" mark on LCD
- Data Hold Indication: Displays "DH" mark on LCD
- Auto Power Off: Approximately 10 minutes after power on
- Withstanding Voltage: AC 2200V for 1 minute max. (Between the core of CT and outer case)
- Operating Temperature: 0℃ to 40℃, 80% RH max. (Without condensation)
- Storage Temperature: -10℃ to 60℃, 70% RH max. (Without condensation)
- Power Supply: 1.55V (SR-44, LR-44) × 2
- Power Consumption: 5mW
- Battery Life: Approximately 50 hours (LR-44)
- Size: 64(W) × 180(H) × 21(D)mm
- Weight: Approximately 135g
- Accessories: Soft case, Instruction manual, Batteries LR-44 (1.55V) × 2
AC Current Measurement Specifications:
- Jaw Opening Capability: 40mmφ
- Range: AC 0~30/300mA, 30/300A, 2 range manual
- Accuracy (at 23℃ ± 5℃, 80% RH or less, 50/60Hz):
- AC 30/300mA: 0.01mA / ±1.2% reading ± 5 digits
- AC 30/300A:
- 0.01A / 0~200A: ±1.2% reading ± 5 digits
- 200~250A: ±3.0% reading ± 5 digits
- 250~300A: ±5.0% reading ± 5 digits
U Type CT Specifications:
- Max. Size of Conductor: 20mmφ
- Range: AC 300A
- Accuracy (at 23℃ ± 5℃, 80% RH or less, 50/60Hz):
- Cable Type/Resolution/Accuracy:
- Single phase IV cable: 0.1A / Approx. ±5%
- Parallel VVF cable: 0.1A / Approx. ±5%
- Three phase VVR cable: 0.1A / Approximate value