Shopping List
Shopping List
PHP -
Image
/
/
/
/
Schneider Electric A9V41263 Vigi iC60 - Earth Leakage add-on Block - 2P - 63A - 30mA - Ac Type
Schneider Electric A9V41263 Vigi iC60 - Earth Leakage add-on Block - 2P - 63A - 30mA - Ac Type
Image
Image
Product Description

Schneider Electric A9V41263 Earth Leakage add-on Block - Vigi iC60

This Acti9 Vigi iC60 is a modular add-on residual current devices. It is a 2P, rated current is 63A, operating voltage is 230VAC to 240VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 30mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of persons and protection of installations. This product is compliant with EN 61009-1 and IEC 61009-1 standard. The Ue rated operational voltage is 230VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 4. The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.165kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature -5°C to +60°C. The storage temperature is -40°C to +85°C.

Specications:

  • Range: Acti9
  • Product or component type: Add-on residual current devices
  • Device short name: Vigi iC60
  • Poles description: 2P
  • [In] rated current: 63 A
  • Earth-leakage sensitivity: 30 mA
  • Earth-leakage protection time delay: Instantaneous
  • Earth leakage protection type: Type AC
  • Network type: AC
  • Network frequency: 50/60 Hz
  • [Ue] rated operational voltage:
    • 230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1
    • 230...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
  • Standards:
    • EN/IEC 61009-1
    • EN/IEC 61009-2-1
  • 9 mm pitches: 4
  • Complementary:
    • Device location in system: Outgoer
    • Residual current tripping technology: Voltage independent
    • [Ui] rated insulation voltage: 500 V AC 50/60 Hz conforming to IEC 60947-2
    • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
  • Range compatibility:
    • Acti 9 Acti9 iC60
    • Acti 9 Acti9 Reflex iC60
  • Product compatibility: Single terminal
  • Local signalling: Trip indicator
  • Mounting mode: Clip-on
  • Mounting support: DIN rail
  • Electrical connection to MCB: By screws
  • Comb busbar and distribution block compatibility: Bottom: YES
  • Dimensions:
    • Height: 91 mm
    • Width: 72 mm
    • Depth: 73.5 mm
    • Net weight: 0.165 kg
  • Connections - terminals:
    • Tunnel type terminal downside for 1 cable(s) 1…35 mm² rigid without cable end
    • Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible without cable end
    • Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible with cable end
  • Wire stripping length: 14 mm for bottom connection
  • Tightening torque: 3.5 N.m bottom
  • Environment:
    • IP degree of protection:
      • IP20 conforming to IEC 60529
      • IP40 (modular enclosure) conforming to IEC 60529
    • Pollution degree: 3 conforming to IEC 60947-2
    • Electromagnetic compatibility: 8/20 µs impulse withstand, 250 A conforming to IEC 61009-1
  • Ambient air temperature:
    • For operation: -5…60 °C
    • For storage: -40…85 °C

₱ 16,968
Quantity:
EA
This item is sold by
Image
MY-1270830467
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Circuit Breaker Accessories from SCHNEIDER ELECTRIC
Source & compare similar products
More from Circuit Breaker Accessories
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image