Shopping List
Shopping List
PHP -
Image
/
/
/
/
Schneider Electric ATV12HU15M2 Variable Speed Drive, Altivar 12, 1.5kW, 2hp, 200 to 240V, 1 Phase, With Heat Sink
Schneider Electric ATV12HU15M2 Variable Speed Drive, Altivar 12, 1.5kW, 2hp, 200 to 240V, 1 Phase, With Heat Sink
Image
Image
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Inverter Drives dimensions or variations
Please select at least one specification below.
Range of Product
Altivar 12
Mounting Mode
Cabinet mount
Standard
UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3
IP Degree of Protection
IP20
Ambient Air Temperature for Operation
-10…50 °C without derating 50…60 °C with current derating 2.2 % per °C
Ambient Air Temperature for Storage
-25…70 °C
Operating Altitude
> 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating
Vibration Resistance
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to EN/IEC 60068-2-6
[Us] Rated Supply Voltage
200...240 V - 15...10 %
Supply Frequency
50/60 Hz +/- 5 %
Switching Frequency
2...16 kHz adjustable 4...16 kHz with derating factor
Noise Level
45 dB
Transmission Rate
9.6 kbit/s 19.2 kbit/s 38.4 kbit/s
Power Dissipation in W
Forced cooling: 72.0 W
Sampling Duration
20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input
Continuous Output Current
7.5 A at 4 kHz
Line Current
17.8 A at 100 V (heavy duty) 14.9 A at 120 V (heavy duty)
Apparent Power
3.6 kVA at 240 V (heavy duty)
Maximum Transient Current
11.2 A during 60 s (heavy duty) 12.4 A during 2 s (heavy duty)
Maximum Input Current
14.9 A
Maximum Output Voltage
240 V
Linearity Error
+/- 0.3 % of maximum value for analogue input
Nominal Output Current
7.5 A
Width
105 mm
This spec is not available in the specification table.
Product or Component Type
Variable speed drive
This spec is not available in the specification table.
Depth
156.2 mm
This spec is not available in the specification table.
Height
142 mm
This spec is not available in the specification table.
Network Frequency
50...60 Hz
This spec is not available in the specification table.
Overvoltage Category
Class III
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3
This spec is not available in the specification table.
Speed Drive Output Frequency
0.5…400 Hz
This spec is not available in the specification table.
Volume of Cooling Air
16 m3/h
This spec is not available in the specification table.
Ambient Air Transport Temperature
-25…70 °C
This spec is not available in the specification table.
Marking
CE
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
This spec is not available in the specification table.
Motor Power kW
1.5 kW
This spec is not available in the specification table.
Motor Power hp
2 hp
This spec is not available in the specification table.
Certifications
NOM CSA C-Tick UL GOST RCM KC
This spec is not available in the specification table.
Operating Position
Vertical +/- 10 degree
This spec is not available in the specification table.
Product Specific Application
Simple machine
This spec is not available in the specification table.
Shock Resistance
15 gn conforming to EN/IEC 60068-2-27 for 11 ms
This spec is not available in the specification table.
Protection Type
Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t
This spec is not available in the specification table.
Connector Type
1 RJ45
This spec is not available in the specification table.
Discrete Input Number
4
This spec is not available in the specification table.
Analogue Input Number
1
This spec is not available in the specification table.
Assembly Style
With heat sink
This spec is not available in the specification table.
Discrete Output Number
2
This spec is not available in the specification table.
Regulation Loop
Adjustable PID regulator
This spec is not available in the specification table.
Maximum Output Frequency
4 kHz
This spec is not available in the specification table.
Physical Interface
2-wire RS 485
This spec is not available in the specification table.
Analogue Output Number
1
This spec is not available in the specification table.
EMC Filter
Integrated
This spec is not available in the specification table.
Method of Access
Server Modbus serial
This spec is not available in the specification table.
Communication Port Protocol
Modbus
This spec is not available in the specification table.
Asynchronous Motor Control Profile
Sensorless flux vector control Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f)
This spec is not available in the specification table.
Nominal Switching Frequency
4 kHz
This spec is not available in the specification table.
Prospective Line Isc
1 kA
This spec is not available in the specification table.
Relay Output Number
1
This spec is not available in the specification table.
Transmission Frame
RTU
This spec is not available in the specification table.
Number of Addresses
1…247
This spec is not available in the specification table.
Data Format
8 bits, configurable odd, even or no parity
This spec is not available in the specification table.
Type of Polarization
No impedance
This spec is not available in the specification table.
4 Quadrant Operation Possible
False
This spec is not available in the specification table.
Acceleration and Deceleration Ramps
U S Linear from 0 to 999.9 s
This spec is not available in the specification table.
Motor Slip Compensation
Adjustable Preset in factory
This spec is not available in the specification table.
Braking to Standstill
By DC injection
This spec is not available in the specification table.
Brake Chopper Integrated
False
This spec is not available in the specification table.
Relative Symmetric Network Frequency Tolerance
5 %
This spec is not available in the specification table.
Base Load Current at High Overload
7.5 A
This spec is not available in the specification table.
With Safety Function Safely Limited Speed (SLS)
False
This spec is not available in the specification table.
With Safety Function Safe Brake Management (SBC/SBT)
False
This spec is not available in the specification table.
With Safety Function Safe Operating Stop (SOS)
False
This spec is not available in the specification table.
With Safety function Safe Position (SP)
False
This spec is not available in the specification table.
With Safety Function Safe Programmable Logic
False
This spec is not available in the specification table.
With Safety Function Safe Speed Monitor (SSM)
False
This spec is not available in the specification table.
With Safety Function Safe Stop 1 (SS1)
False
This spec is not available in the specification table.
With sft fct Safe Stop 2 (SS2)
False
This spec is not available in the specification table.
With Safety Function Safe Torque Off (STO)
False
This spec is not available in the specification table.
With Safety Function Safely Limited Position (SLP)
False
This spec is not available in the specification table.
With Safety Function Safe Direction (SDI)
False
This spec is not available in the specification table.
Environmental Class (During Operation)
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
This spec is not available in the specification table.
Maximum Acceleration Under Shock Impact (During Operation)
150 m/s² at 11 ms
This spec is not available in the specification table.
Maximum Acceleration Under Vibrational Stress (During Operation)
10 m/s² at 13...200 Hz
This spec is not available in the specification table.
Maximum Deflection Under Vibratory Load (During Operation)
1.5 mm at 2...13 Hz
This spec is not available in the specification table.
Frequency Resolution
Analog input: converter A/D, 10 bits Display unit: 0.1 Hz
This spec is not available in the specification table.
Time Constant
20 ms +/- 1 ms for reference change
This spec is not available in the specification table.
Communication Service
Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43)
This spec is not available in the specification table.
Electromagnetic Emission
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2...16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 m
This spec is not available in the specification table.
Insulation
Electrical between power and control
This spec is not available in the specification table.
Speed Range
1…20
This spec is not available in the specification table.
Transient Overtorque
150…170 % of nominal motor torque depending on drive rating and type of motor
This spec is not available in the specification table.
Tightening Torque
1.2 N.m
This spec is not available in the specification table.
Product Description
₱ 42,726
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Inverter Drives
13 Items
inverter-drives-img
Local Signalling
3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, Local diagnostic: 3 LED (mono/dual colour) Embedded communication status: 5 LED (dual colour) Communication module status: 2 LED (dual colour) Presence of voltage: 1 LED (red), 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage 3 LEDs for local diagnostic, 1 LED (red) for DC bus energized
Range of Product
Altivar Process ATV600, Altivar 12, Altivar Machine ATV320, Easy Altivar 310, Altivar 212
Mounting Mode
Wall mount, Cabinet mount, Wall Mount, DIN Rail, Cabinet Mount
Standard
IEC 61800-3 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 UL Type 1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C2 IEC 61800-3 IEC 61800-3 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-5-1 EN 55011 class A group 1 IEC 61800-3 environments 2 category C2 EN 61800-3 category C3 IEC 61800-5-1 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C1, CE, CSA, UL, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, NOM 117, RCM, UL, ATEX, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, TUV, UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 13849-1, IEC 60721-3, IEC 61000-3-12, IEC 61508, UL 508C
IP Degree of Protection
IP20, IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to IEC 60529 IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529 IP41 on upper part conforming to IEC 61800-5-1 IP41 on upper part conforming to IEC 60529, IP55 conforming to IEC 61800-5-1 IP55 conforming to IEC 60529, IP55, IP54
Ambient Air Temperature for Operation
-10…50 °C without derating 50…60 °C with derating factor, -10…55 °C without derating 55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C, 40…50 °C (with derating factor) -15…40 °C (without derating), -15…50 °C (without derating) 50…60 °C (with derating factor), -10…40 °C (without derating) 40…50 °C (with derating factor)
Operating Altitude
<= 3000 m with current derating above 1000m, <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m, 1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating, 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating, <= 1000 m without derating
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Inverter Drives from SCHNEIDER ELECTRIC
Source & compare similar products
More from Inverter Drives
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image