Shopping List
Shopping List
PHP -
Image
/
/
/
/
Schneider Electric CA3KN22BD Control Relay, Tesys K, 4P(2NO+2NC), 690V, 24V Dc Standard Coil
Schneider Electric CA3KN22BD Control Relay, Tesys K, 4P(2NO+2NC), 690V, 24V Dc Standard Coil
Image
Image
Specifications
infotip-icon
View other Control Relays dimensions or variations
Please select at least one specification below.
Utilisation Category
AC-15 DC-13
Standards
EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14
Mounting Support
Rail Plate
Ip Degree Of Protection
IP2X
Ambient Air Temperature For Operation
-25…50 °C
Mechanical Durability
20 Mcycles
Ambient Air Temperature For Storage
-50…80 °C
[Ith] Conventional Free Air Thermal Current
10 A (at 50 °C)
Minimum Switching Current
5 mA
Insulation Resistance
> 10 MOhm
Product Certifications
CB Scheme CCC UL CSA EAC CE UKCA
Connections - Terminals
Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible without cable end
This spec is not available in the specification table.
Tightening Torque
1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 26 mm
This spec is not available in the specification table.
Immunity To Microbreaks
2 ms
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys CAK
This spec is not available in the specification table.
Operating Altitude
2000 m without derating
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
<= 690 V <= 400 Hz
This spec is not available in the specification table.
Contactor Application
Control circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
24 V DC
This spec is not available in the specification table.
Pole Contact Composition
2 NO + 2 NC
This spec is not available in the specification table.
Irms Rated Making Capacity
110 A conforming to IEC 60947
This spec is not available in the specification table.
Associated Fuse Rating
10 A gG conforming to IEC 60947 10 A gG conforming to VDE 0660
This spec is not available in the specification table.
Control Circuit Type
DC standard
This spec is not available in the specification table.
Control Circuit Voltage Limits
Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.1...0.75 Uc (at <50 °C)
This spec is not available in the specification table.
Heat Dissipation
3 W
This spec is not available in the specification table.
Operating Time
10 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing 15 ms coil de-energisation and NC closing 25...35 ms coil energisation and NC opening
This spec is not available in the specification table.
Maximum Operating Rate
10000 cyc/h
This spec is not available in the specification table.
Minimum Switching Voltage
17 V
This spec is not available in the specification table.
Protective Treatment
TC conforming to IEC 60068
This spec is not available in the specification table.
Flame Retardance
V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
This spec is not available in the specification table.
Mechanical Robustness
Vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
This spec is not available in the specification table.
Inrush Power In W
3 W (at 20 °C)
This spec is not available in the specification table.
Hold-In Power Consumption In W
3 W at 20 °C
This spec is not available in the specification table.
Non Overlap Distance
0.5 mm
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Control Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Control Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image