Shopping List
Shopping List
PHP -
Image
/
/
/
/
Schneider Electric CAD32F7 Control Relay, Tesys Deca, 3NO+2NC, 0 to 690V, 110VAC 50/60Hz Standard Coil, Screw Clamp
Schneider Electric CAD32F7 Control Relay, Tesys Deca, 3NO+2NC, 0 to 690V, 110VAC 50/60Hz Standard Coil, Screw Clamp
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Control Relays dimensions or variations
Please select at least one specification below.
Utilisation Category
AC-15 AC-14 DC-13
Standards
EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1
[Ui] Rated Insulation Voltage
600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1
Mounting Support
Rail Plate
Ip Degree Of Protection
IP2X front face conforming to VDE 0106
Ambient Air Temperature For Operation
-40…60 °C 60…70 °C with derating
Mechanical Durability
30 Mcycles
Ambient Air Temperature For Storage
-60…80 °C
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C)
Minimum Switching Current
5 mA
Insulation Resistance
> 10 MOhm
Product Certifications
CB CCC UL CSA EAC CE UKCA
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947
This spec is not available in the specification table.
Connections - Terminals
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
This spec is not available in the specification table.
Tightening Torque
1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
This spec is not available in the specification table.
Range
TeSys TeSys Deca
This spec is not available in the specification table.
Product Name
TeSys CAD
This spec is not available in the specification table.
Operating Altitude
0...3000 m
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
<= 690 V AC 25...400 Hz
This spec is not available in the specification table.
Contactor Application
Control circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
110 V AC 50/60 Hz
This spec is not available in the specification table.
Pole Contact Composition
3 NO + 2 NC
This spec is not available in the specification table.
Irms Rated Making Capacity
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
100 A - 1 s 120 A - 500 ms 140 A - 100 ms
This spec is not available in the specification table.
Associated Fuse Rating
10 A gG conforming to IEC 60947-5-1
This spec is not available in the specification table.
Control Circuit Type
AC at 50/60 Hz
This spec is not available in the specification table.
Control Circuit Voltage Limits
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
This spec is not available in the specification table.
Inrush power in VA
70 VA 50 Hz (at 20 °C)
This spec is not available in the specification table.
Hold-In Power Consumption In Va
8 VA 50 Hz (at 20 °C)
This spec is not available in the specification table.
Operating Time
12...22 ms coil energisation and NO closing 4...12 ms coil de-energisation and NO opening 4...19 ms coil energisation and NC opening 6...17 ms coil de-energisation and NC closing
This spec is not available in the specification table.
Maximum Operating Rate
180 cyc/mn
This spec is not available in the specification table.
Minimum Switching Voltage
17 V
This spec is not available in the specification table.
Non-Overlap Time
1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068
This spec is not available in the specification table.
Mechanical Robustness
Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Control Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Control Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image