Shopping List
Shopping List
PHP -
Image
/
/
/
/
Schneider Electric LR2K0303 Differential Thermal Overload Relay, Tesys K, 0.23...0.36A, Class 10A
Schneider Electric LR2K0303 Differential Thermal Overload Relay, Tesys K, 0.23...0.36A, Class 10A
Image
Image
Specifications
infotip-icon
View other Overload Relays dimensions or variations
Please select at least one specification below.
Network Type
AC DC
Network Frequency
<= 400 Hz
Standards
NF C 63-650 IEC 60947 VDE 0660 BS 4941
[Ui] Rated Insulation Voltage
Power circuit: 690 V conforming to BS 4941 Power circuit: 690 V conforming to IEC 60947 Power circuit: 750 V conforming to VDE 0110 group C Power circuit: 600 V conforming to CSA C22.2 No 14
[Uimp] Rated Impulse Withstand Voltage
6 kV
Ambient Air Temperature For Operation
-20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947
Ambient Air Temperature For Storage
-40…70 °C
[Ith] Conventional Free Air Thermal Current
6 A for signalling circuit
Auxiliary Contact Composition
1 NO + 1 NC
Thermal Protection Adjustment Range
0.23…0.36 A
Local Signalling
Trip indicator (yellow)
This spec is not available in the specification table.
Control Type
Red push-button: trip test function Blue push-button: stop and manual reset selector switch: manual or automatic reset
This spec is not available in the specification table.
Device Short Name
LR2K
This spec is not available in the specification table.
Product Or Component Type
Differential thermal overload relay
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys LRK
This spec is not available in the specification table.
Mounting Support
Under contactor Plate, with specific accessories Rail, with specific accessories
This spec is not available in the specification table.
Connections - Terminals
Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
This spec is not available in the specification table.
Ip Degree Of Protection
IP2X conforming to IEC 60529
This spec is not available in the specification table.
Operating Altitude
2000 m without derating
This spec is not available in the specification table.
Tightening Torque
1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
<= 690 V for power circuit 690 V AC AC-15 for signalling circuit 250 V DC DC-13 for signalling circuit
This spec is not available in the specification table.
Associated Fuse Rating
6 A gG for signalling circuit conforming to VDE 0660 6 A gG for signalling circuit conforming to IEC 60947
This spec is not available in the specification table.
Product Certifications
UL CSA UKCA
This spec is not available in the specification table.
Protective Treatment
TC conforming to IEC 60068 TC conforming to DIN 50016
This spec is not available in the specification table.
Fire Resistance
850 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Product Compatibility
LC7K LC1K LP1K LP4K
This spec is not available in the specification table.
Mechanical Robustness
Shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
This spec is not available in the specification table.
Phase Failure Sensitivity
Yes conforming to IEC 60947-4-1
This spec is not available in the specification table.
Relay Application
Motor protection
This spec is not available in the specification table.
Power Dissipation Per Pole
2 W
This spec is not available in the specification table.
Flame Retardance
V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
This spec is not available in the specification table.
Thermal Overload Class
Class 10A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Product Description
₱ 3,645
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Overload Relays
53 Items
overload-relays-img
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5, IEC 60255-17 IEC 60947-4-1 IEC 60255-8 VDE 0660 EN 60947-4-1, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 EN 50495, EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
[Ui] Rated Insulation Voltage
Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC conforming to UL Power circuit: 690 V AC conforming to IEC 60947-4-1, Power circuit: 1000 V AC conforming to IEC 60947-4, Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1, Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL, Power circuit: 1000 V conforming to IEC 60947-4-1
Ambient Air Temperature For Operation
-20…55 °C without derating conforming to IEC 60947 -30…60 °C with derating conforming to IEC 60947, -20…55 °C conforming to IEC 60255-8, -20…60 °C without derating conforming to IEC 60947-4-1, -25 → +60 °C, -20 → +60 °C
[Ith] Conventional Free Air Thermal Current
6 A for signalling circuit, 3 A for signalling circuit, 5 A for signalling circuit, 3 A for control circuit, 5 A for control circuit
Thermal Protection Adjustment Range
80…104 A, 30…40 A, 30…38 A, 48…65 A, 110…140 A
[Us] Rated Supply Voltage
100...120 V AC, 200...240 V AC, 24 V DC, 24 V ac/dc, 690 V ac
-
Highly Matched Items