DC Current Measurement:
- Range: 0.0…659.9 A; 660…1000 A
- Resolution: 0.1 A; 1 A
- Accuracy:
- 0.0…659.9 A: ±(2.5% of measured value + 5 digits)
- 660…1000 A: ±(2.8% of measured value + 8 digits)
DC Voltage Measurement:
- Range: 0.000…6.599 V; 6.60…65.99 V; 66.0…600.0 V
- Resolution: 0.001 V; 0.01 V; 0.1 V
- Accuracy: ±(1.5% of measured value + 3 digits)
Resistance Measurement:
- Range:
- 0.0…659.9 Ω; 0.660…6.599 kΩ; 6.60…65.99 kΩ; 66.0…659.9 kΩ
- 0.660…6.599 MΩ; 6.60…66.00 MΩ
- Resolution: 0.1 Ω; 0.001 kΩ; 0.01 kΩ; 0.1 kΩ; 0.001 MΩ; 0.01 MΩ
- Accuracy:
- 0.0…659.9 Ω: ±(1.0% of measured value + 4 digits)
- 0.660…6.599 MΩ: ±(2.5% of measured value + 3 digits)
- 6.60…66.00 MΩ: ±(3.5% of measured value + 5 digits)
Duty Cycle Measurement:
- Range: 10.0%...94.9%
- Resolution: 0.1%
- Accuracy: unspecified; frequency range: 30 Hz...15 kHz
AC Current Measurement (True RMS):
- Range: 0.0…659.9 A; 660…1000 A
- Resolution: 0.1 A; 1 A
- Accuracy:
- 0.0…659.9 A: ±(2.5% of measured value + 8 digits) for 45...65 Hz
- 660…1000 A: ±(2.8% of measured value + 8 digits) for 45...65 Hz
AC Voltage Measurement (True RMS):
- Range: 0.000…6.599 V; 6.60…65.99 V; 66.0…600.0 V
- Resolution: 0.001 V; 0.01 V; 0.1 V
- Accuracy: ±(1.8% of measured value + 5 digits) for 45...65 Hz
Frequency Measurement:
- Range: 30.00…659.9 Hz; 0.660…6.599 kHz; 6.60…15.00 kHz
- Resolution: 0.1 Hz; 0.001 kHz; 0.01 kHz
- Accuracy: ±(1.2% of measured value + 2 digits)
- Sensitivity:
- 30 Hz...5 kHz: 10 V RMS min
- 5 kHz...15 kHz: 40 V RMS min. for 20...80% duty cycle
Temperature:
- Range: -20...+760°C; -4...+1400°F
- Resolution: 1°C; 1°F
- Accuracy: ±(3% of measured value + 5°C); ±(3% of measured value + 9°F) (probe accuracy not included)