Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Schneider Electric C11B3TM063B Circuit Breaker Compact Nsxm B (25kA pada 415VAC), 3 Tiang 3d, 63A Rating Tmd Trip Unit, Lug Kompresi dan Konektor Busbar
Schneider Electric C11B3TM063B Circuit Breaker Compact Nsxm B (25kA pada 415VAC), 3 Tiang 3d, 63A Rating Tmd Trip Unit, Lug Kompresi dan Konektor Busbar
Image
Image
Specifications
infotip-icon
View other Circuit Breaker dimensions or variations
Please select at least one specification below.
Ambient air temperature for operation
-25…70 °C
Poles Description
3P
Protected Poles Description
3D
Network Type
AC
[In] Rated Current
63 A at 40 °C
Network Frequency
50/60 Hz
Standards
EN/IEC 60947
[Ui] Rated Insulation Voltage
800 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage
8 kV
Ip Degree Of Protection
IP40 conforming to IEC 60529
Pollution Degree
3 conforming to IEC 60664-1
Ambient Air Temperature For Storage
-50…85 °C
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz
Trip Unit Rating
63 A at 40 °C
Trip Unit Technology
Thermal-magnetic
This spec is not available in the specification table.
Trip Unit Protection Functions
LI
This spec is not available in the specification table.
Control Type
Toggle
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Trip Unit Name
TM-D
This spec is not available in the specification table.
Device Short Name
NSXm 63B
This spec is not available in the specification table.
Product Or Component Type
Circuit breaker
This spec is not available in the specification table.
Range
ComPacT new generation
This spec is not available in the specification table.
Product Name
ComPacT NSXm new generation
This spec is not available in the specification table.
Range Of Product
ComPacT NSXm new generation
This spec is not available in the specification table.
Device Application
Distribution
This spec is not available in the specification table.
Connection Pitch
35 mm with spreaders 27 mm without spreaders
This spec is not available in the specification table.
Utilisation Category
Category A
This spec is not available in the specification table.
Suitability For Isolation
Yes conforming to IEC 60947-2
This spec is not available in the specification table.
Mounting Support
Backplate
This spec is not available in the specification table.
Local Signalling
Flag (green) for presence of auxiliary contacts
This spec is not available in the specification table.
Mechanical Durability
20000 cycles
This spec is not available in the specification table.
Electrical Durability
20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
This spec is not available in the specification table.
Earth-Leakage Protection
Without
This spec is not available in the specification table.
Ik Degree Of Protection
IK07 conforming to IEC 62262
This spec is not available in the specification table.
Upside Connection
Front
This spec is not available in the specification table.
Downside Connection
Front
This spec is not available in the specification table.
Colour
Grey (RAL 7016)
This spec is not available in the specification table.
Performance Level
B 25 kA 415 V AC
This spec is not available in the specification table.
Number Of Slots For Electrical Auxiliaries
1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX
This spec is not available in the specification table.
9 Mm Pitches
9 module
This spec is not available in the specification table.
Relative Humidity
0…95 %
This spec is not available in the specification table.
Operating Altitude
2000 m without derating 5000 m with derating
This spec is not available in the specification table.
Power Dissipation Per Pole
5.58 W
This spec is not available in the specification table.
[Ics] Rated Service Short-Circuit Breaking Capacity
50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Mounting Position
Horizontal and vertical Flat on the back
This spec is not available in the specification table.
[Icu] Rated Ultimate Short-Circuit Breaking Capacity
50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Long-Time Pick-Up Adjustment Type Ir (Thermal Protection)
Adjustable
This spec is not available in the specification table.
[Ir] Long-Time Protection Pick-Up Adjustment Range
0.7...1 x In
This spec is not available in the specification table.
Long-Time Protection Delay Adjustment Type Tr
Fixed
This spec is not available in the specification table.
Instantaneous Protection Pick-Up Adjustment Type Ii
Fixed
This spec is not available in the specification table.
[Ii] Instantaneous Protection Pick-Up Adjustment Range
800 A
This spec is not available in the specification table.
Connection Terminals
compression lug/busbar
This spec is not available in the specification table.
Deskripsi Produk

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Circuit Breaker dari SCHNEIDER ELECTRIC
Temukan dan bandingkan barang serupa
Lebih Dari Circuit Breaker
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas
Image