Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Schneider Electric GV2RT06 Tesys GV2 - Pemutus Arus - magnetik termal - 1…1.6 a - Terminal Penjepit Sekrup
Schneider Electric GV2RT06 Tesys GV2 - Pemutus Arus - magnetik termal - 1…1.6 a - Terminal Penjepit Sekrup
Image
Image
Specifications
infotip-icon
View other Motor Protection Circuit Breakers dimensions or variations
Please select at least one specification below.
Poles
3P
Rated Current
1.6 A
Trip Unit Technology
Thermal-magnetic
Control Type
Toggle
Range
TeSys Deca
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-2
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-20…60 °C
Ambient Air Temperature for Storage
-40…80 °C
Operating Altitude
2000 m
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity
100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Width
45 mm
This spec is not available in the specification table.
Device Short Name
GV2RT
This spec is not available in the specification table.
Product Name
TeSys GV2 TeSys Deca
This spec is not available in the specification table.
Depth
78.5 mm
This spec is not available in the specification table.
Device Application
Motor protection Motor
This spec is not available in the specification table.
Network Type
AC
This spec is not available in the specification table.
Network Frequency
50/60 Hz conforming to IEC 60947-4-1
This spec is not available in the specification table.
Utilisation Category
Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to IEC 60947-1 § 7-1-6
This spec is not available in the specification table.
Standards
EN/IEC 60947-2 EN/IEC 60947-4-1
This spec is not available in the specification table.
Height
89 mm
This spec is not available in the specification table.
Mechanical Durability
100000 cycles
This spec is not available in the specification table.
Electrical Durability
100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
This spec is not available in the specification table.
Tightening Torque
1.7 N.m - on screw clamp terminal
This spec is not available in the specification table.
Fixing Mode
35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)
This spec is not available in the specification table.
Motor Power kW
0.18 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.25 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.37 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.55 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.37 kW at 440 V AC 50/60 Hz motor protection high peak current 0.55 kW at 440 V AC 50/60 Hz motor protection high peak current 0.37 kW at 500 V AC 50/60 Hz motor protection high peak current 0.55 kW at 500 V AC 50/60 Hz motor protection high peak current 0.75 kW at 500 V AC 50/60 Hz motor protection high peak current 0.75 kW at 690 V AC 50/60 Hz motor protection high peak current 1.1 kW at 690 V AC 50/60 Hz motor protection high peak current 0.4 kW at 230/240 V AC 50/60 Hz transformer protection 0.63 kW at 400/415 V AC 50/60 Hz transformer protection
This spec is not available in the specification table.
[Ith] conventional free air thermal current
1.6 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Power dissipation per pole
2.5 W
This spec is not available in the specification table.
Product certifications
CCC UL CSA EAC LROS (Lloyds register of shipping) BV UKCA
This spec is not available in the specification table.
Climatic withstand
conforming to IACS E10
This spec is not available in the specification table.
Fire resistance
960 °C conforming to IEC 60695-2-11
This spec is not available in the specification table.
Mechanical robustness
Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz
This spec is not available in the specification table.
Thermal protection adjustment range
1…1.6 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Magnetic tripping current
33 A
This spec is not available in the specification table.
Rated duty
Continuous conforming to IEC 60947-4-1
This spec is not available in the specification table.
IK Degree of Protection
IK04
This spec is not available in the specification table.
Deskripsi Produk

Pemutus Sirkuit Motor Schneider Electric GV2RT06, Tesys Deca,3P,1-1,6A, Magnetik Termal, Terminal Klem Sekrup, Pegangan Toggle

Pemutus sirkuit motor TeSys GV, 3 kutub (3P), 1,6A/690V, untuk aplikasi motor puncak arus start tinggi 0,37-0,55kW@400V. Ini memberikan perlindungan termal-magnetik dengan rentang pengaturan termal 1-1,6A, tingkat tripping magnetik pada 20xIn, kapasitas pemutusan tinggi Icu 100kA. Koneksi dengan terminal penjepit sekrup. Kontrol start-stop dengan beralih dijamin untuk 100.000 siklus AC-3. Dapat digunakan untuk proteksi aplikasi trafo 3 fasa. Bersertifikasi multi standar (IEC, UL, CSA, CCC, EAC, Marine), memenuhi standar Green Premium (RoHS/REACh).

Rp 1.649.128
Kuantitas:
EA
This item is sold by
Image
MY-2155714050
Highly Matched Items
View items that have the same or are a close match to the specifications of this item