Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Kontaktor Schneider Electric LC1D128P7, Tesys Deca, 4P(2NO+2NC), AC-1, <=440V, 25A, Koil 230VAC 50/60Hz, Terminal Penjepit Sekrup
Kontaktor Schneider Electric LC1D128P7, Tesys Deca, 4P(2NO+2NC), AC-1, <=440V, 25A, Koil 230VAC 50/60Hz, Terminal Penjepit Sekrup
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Contactors dimensions or variations
Please select at least one specification below.
Device Short Name
LC1D
Range Of Product
TeSys Deca
Depth
92 mm
Pole Contact Composition
2 NO + 2 NC
Poles Description
4P
Contactor Application
Resistive load
Compatibility Code
LC1D
This spec is not available in the specification table.
Standards
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947
This spec is not available in the specification table.
Mounting Support
Rail Plate
This spec is not available in the specification table.
Connections - Terminals
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
This spec is not available in the specification table.
Height
85 mm
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 front face conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Mechanical Durability
15 Mcycles
This spec is not available in the specification table.
Electrical Durability
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
This spec is not available in the specification table.
Operating Altitude
0...3000 m
This spec is not available in the specification table.
Tightening Torque
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC
This spec is not available in the specification table.
[Ie] Rated Operational Current
25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
230 V AC 50/60 Hz
This spec is not available in the specification table.
Inrush power in VA
70 VA 60 Hz cos phi 0.75 (at 20 °C)<br />70 VA 50 Hz cos phi 0.75 (at 20 °C)
This spec is not available in the specification table.
Hold-in power consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 20 °C)<br />7 VA 50 Hz cos phi 0.3 (at 20 °C)
This spec is not available in the specification table.
Heat dissipation
2…3 W at 50/60 Hz
This spec is not available in the specification table.
Utilisation Category
AC-1 AC-3 AC-3e AC-4
This spec is not available in the specification table.
Protective Cover
With
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
25 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit
This spec is not available in the specification table.
Irms Rated Making Capacity
250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
This spec is not available in the specification table.
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
105 A 40 °C - 10 s for power circuit 210 A 40 °C - 1 s for power circuit 30 A 40 °C - 10 min for power circuit 61 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
This spec is not available in the specification table.
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit
This spec is not available in the specification table.
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
This spec is not available in the specification table.
Power Dissipation Per Pole
1.56 W AC-1
This spec is not available in the specification table.
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
This spec is not available in the specification table.
Control Circuit Type
AC at 50/60 Hz
This spec is not available in the specification table.
Coil Technology
Without built-in suppressor module
This spec is not available in the specification table.
Control Circuit Voltage Limits
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
This spec is not available in the specification table.
Operating Time
12...22 ms closing 4...19 ms opening
This spec is not available in the specification table.
Auxiliary Contact Composition
3600 cyc/h 60 °C
This spec is not available in the specification table.
Maximum Operating Rate
1 NO + 1 NC
This spec is not available in the specification table.
Auxiliary Contacts Type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
This spec is not available in the specification table.
Signalling Circuit Frequency
25...400 Hz
This spec is not available in the specification table.
Minimum Switching Voltage
17 V for signalling circuit
This spec is not available in the specification table.
Minimum Switching Current
5 mA for signalling circuit
This spec is not available in the specification table.
Insulation Resistance
> 10 MOhm for signalling circuit
This spec is not available in the specification table.
Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068-2-30
This spec is not available in the specification table.
Climatic Withstand
conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat
This spec is not available in the specification table.
Permissible Ambient Air Temperature Around The Device
-40…60 °C 60…70 °C with derating
This spec is not available in the specification table.
Fire Resistance
850 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Flame Retardance
V1 conforming to UL 94
This spec is not available in the specification table.
Mechanical Robustness
Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms)
This spec is not available in the specification table.
Deskripsi Produk

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contactors dari SCHNEIDER ELECTRIC
Temukan dan bandingkan barang serupa
Lebih Dari Contactors
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas
Image