Shopping List
Shopping List
PHP -
Image
/
/
/
/
Schneider Electric GVAN11 Auxiliary Contact Block,tesys Deca,1NO+1NC,left Side Mounting
Schneider Electric GVAN11 Auxiliary Contact Block,tesys Deca,1NO+1NC,left Side Mounting
Image
Image
Specifications
infotip-icon
View other Auxiliary Contact dimensions or variations
Please select at least one specification below.
Colour
Dark grey
Range
TeSys TeSys Deca
[Ui] Rated Insulation Voltage
600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14
[Ue] Rated Operational Voltage
48...690 V AC 24...240 V DC
Pole contact composition
1 NO + 1 NC
Width
9.3 mm
This spec is not available in the specification table.
Device Short Name
GVAN
This spec is not available in the specification table.
Depth
66 mm
This spec is not available in the specification table.
Product certifications
UKCA
This spec is not available in the specification table.
Height
89 mm
This spec is not available in the specification table.
Mechanical Durability
100000 cycles
This spec is not available in the specification table.
Tightening Torque
1.4 N.m - on screw clamp terminals
This spec is not available in the specification table.
Environmental Characteristic
Normal environment
This spec is not available in the specification table.
[Ith] conventional free air thermal current
6 A
This spec is not available in the specification table.
Minimum switching voltage
17 V
This spec is not available in the specification table.
Minimum Switching Current
5 mA
This spec is not available in the specification table.
Product Compatibility
GV2ME GV2RT GV2L GV3P GV3L GV2LE GV2P
This spec is not available in the specification table.
Protection type
GB2CB... circuit breaker GG fuse 10 A
This spec is not available in the specification table.
Mounting location
Left side
This spec is not available in the specification table.
Rated operational power in VA
300 VA at 48 V AC-15 - electrical durability: 100000 cycles 414 VA at 690 V AC-15 - electrical durability: 100000 cycles 500 VA at 110…127 V AC-15 - electrical durability: 100000 cycles 500 VA at 500 V AC-15 - electrical durability: 100000 cycles 650 VA at 440 V AC-15 - electrical durability: 100000 cycles 720 VA at 230…240 V AC-15 - electrical durability: 100000 cycles 850 VA at 380…415 V AC-15 - electrical durability: 100000 cycles
This spec is not available in the specification table.
Rated operational power in W
120 W at 240 V DC-13 - electrical durability: 100000 cycles 140 W at 110 V DC-13 - electrical durability: 100000 cycles 140 W at 24 V DC-13 - electrical durability: 100000 cycles 180 W at 60 V DC-13 - electrical durability: 100000 cycles 240 W at 48 V DC-13 - electrical durability: 100000 cycles
This spec is not available in the specification table.
Product Description
₱ 955
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
35 Items
auxiliary-contact-img
Rated Current
AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
Range
Acti9, EasyPact, TeSys, TeSys TeSys Deca, Tesys
Standard
UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 EN 50012, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012
[Ui] Rated Insulation Voltage
500 V, 690 V conforming to IEC 60947-5-1 600 V conforming to UL 600 V conforming to CSA, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14, 250 V conforming to CSA 250 V conforming to IEC 60947-5-1 250 V conforming to UL
Ambient Air Temperature for Operation
-25…60 °C, -35…70 °C, -20…50 °C, -25…50 °C, -5…60 °C
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz, 24...240 V AC 24...60 V DC, 48...690 V AC 24...240 V DC, 690 V AC 25...400 Hz, <= 250 V AC <= 250 V DC
Pole contact composition
2 NO + 2 NC, 4 NC, 1 NO + 3 NC, 2 NO, 3 NO + 1 NC
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image